b. All PJL commands supported and their parameter setting range
The following Table shows all the PJL commands (19 commands) used for PJL support, their functions and parameter setting ranges.
(PJL commands and their functions)
Command Name
Command Function
Kernel Commands
UEL(Universal Exit Language)
Must be inserted in the beginning mode and end, when exiting from current printer
language for controlling by PJL.
COMMENT
Gives comment.
ENTER
Selects printer language for processing job.
Job
JOB
Informs printer of the beginning of job.
Separation
Commands
EOJ
Informs printer of the job end. Resets page count.
Environment
DEFAULT
Default setting (to EEPROM).
Commands
User Default Environment
SET
(Temporary) setting during PJL job. PJL Current Environment
PJL Currnt Environment
INITIALIZE
Resets current value to factory default value (INITIALIZE).
RESET
Resets current value to default value.
Status
INQUIRE
Requests the sending of current value (PJL Current Environment).
Readback
DINQUIRE
Request the sending of information of default value (User Default Environment).
Commands
ECHO
Used to synchronize host and printer. It clarifies time, and which job is printing
INFO
Requests the sending of printer’s specific information (model No., configuration,
memory amount, etc.)
USTATUS
Sets if unsolicited message (error, etc.) is automatically returned or not.
USTATUSOFF
Deletes the request for unsolicited message.
Device
RDYMSG
Changes control panel message. Printer remains online.
Attendance
OPMSG
Changes control panel message, and sets printer offline.
Commands
STMSG
Shows which key operator pressed to set printer online
CLEAR
Performs the same operation as when the key is pressed on the control panel.
(Each command parameter and its setting range)
Parameter which is not supported is struck out.
Parameter which must be created newly for Color Laser Printer and setting range which is different from HP original are painted gray.
Commands and parameters which are not marked comply with HP originals. Added command and parameter must operate as described.
Command
Parameter
Range
UEL
None
COMMENT
Remarks
(Comment sentence)
ASCII CODE 33 to 255
and <WS>
ENTER
LANGUAGE
PCL
(Personality)
PostScript
JOB
NAME
ASCII CODE 33 to 255, (Job Name)
<SP>, <HT>
START
1 to 2147483647 (Page where job begins)
END
1 to 2147483647 (Page where job ends)
EOJ
NAME
ASCII CODE 33 to 255
<SP>, <HT>
SHARP SERVICE MANUAL JX8200SM [13] ELECTRICAL SECTION
13 – 30
Содержание JX-8200
Страница 201: ...14 2 ...
Страница 202: ...14 3 ...
Страница 203: ...14 4 ...
Страница 204: ...14 5 ...