Operating Instructions – MOVIDRIVE® MDR60A/61B
123
15
Operating displays
Operation and Service (MDR60A1320-503-00)
15.2.2 LED signals
Error
code
LED displays
Meaning
Opera-
tion
(Green
)
Phase
failure
(Red)
Over-
cur-
rent /
UCE
(Red)
Over-
tempera-
ture
(Orange)
Group
fault
(Yellow)
During initial startup
During operation
1
X
-
-
-
The unit is ready for operation after
about 1 s.
Unit in operation
2
X
-
-
-
-
Unit ready for operation but no regeneration
→
check DC fuses
3
X
-
-
X
X
-
Overtemperature of the heat
sink.
→
Error message cannot be
confirmed while temperature is
excessive.
4
X
-
-
-
X
-
Just like error code 3.
→
Heat sink temperature has
dropped and error can be con-
firmed.
5
X
-
-
-
X
Unit has been turned off (external OFF).
→
Enable signal required
6
X
-
-
-
X
Triggering the overvoltage monitoring.
Enable signal is required if the supply voltage has dropped to nominal
value
7
X
X
-
-
X
Incorrect rotating field or phase
Phase failure has been
detected
→
Confirmation necessary.
8
X
-
X
-
X
-
Overcurrent (three-phase side)
has been detected.
→
Confirmation necessary.
9
X
X
X
-
X
Error codes 7 and 8
Overcurrent has been detected
with simultaneous phase fail-
ure detection due to commuta-
tion notch.
10
X
X
X
X
X
Several errors occurring at the same time.
11
-
-
-
-
-
Unit not operating, at least two phases without voltage.
13
X
X
-
-
-
-
Massive commutation notch
has been detected, no discon-
nection because jumpers 3 and
7 are open.
→
Operation can be resumed,
recommendation for improved
supply system.
Содержание MDR60A