Operating Instructions – MOVIDRIVE® MDR60A/61B
117
14
Important notes on configuration
Configuration (MDR60A1320-503-00)
14
Configuration (MDR60A1320-503-00)
The coding of jumpers (jumpers J3, J5, J6, J7, J8) on the control card offers different
control options and different internal functions for certain error messages.
The different terms that result from certain coding options are explained below.
14.1 Important notes on configuration
14.1.1 Autostart
"Autostart" means that the unit starts up automatically with a delay of 1 s once the supply
voltage has been applied. The "Autostart" function is coded with jumper J1 on the control
card and may not be altered.
14.1.2 Switch-off – switch-on
"Switch-off" means that control of the power semiconductors and regeneration is inter-
rupted and braking operation of the drive controllers is no longer possible.
"Switch-on" means control of the power semiconductors is being activated.
14.1.3 Save
The unit comes equipped with an error memory that can be assigned certain errors.
Saved error messages must be confirmed via reset or interruption of the supply voltage
of the control component power supply. "Save" always results in a simultaneous "switch-
off" and dropping out of the centralized alarm relay.
14.1.4 Confirmation
Once an error has been remedied, the error memory will have to be confirmed with the
ON confirmation key or disconnection of the three-phase power supply.
NOTICE
• Confirmation of an excessive DC link voltage, i.e. during braking operation, is not
permitted and may destroy the unit!