6
Startup
Detailed motor selection table for startup via DIP switch S3
Operating Instructions – MOVIMOT
®
flexible
154
Motor
Electronics cover
DIP switch S3
Motor type
Brake
Type des-
ignation
Nominal out-
put current
Connec-
tion type
Motor assignment in rela-
tion to the inverter power
Type/nom-
inal voltage
S3/1
S3/2
S3/3 S3/4
Motor power
DRN90S4
0020
2.0 A
W
0
m
1
BE2B/230 V
0
0025
2.5 A
W
0
m
1
0032
3.2 A
W
0
0
0
Adjusted
m
1
BE1C/230 V
1
0040
4.0 A
W
0
1
0
1 stage smaller
m
1
0
0
Adjusted
0055
5.5 A
W
0
0
1
2 stages smaller
m
1
1
0
1 stage smaller
DRN90L4
0020
2.0 A
W
0
m
1
BE2B/230 V
0
0025
2.5 A
W
0
m
1
0032
3.2 A
W
0
m
1
BE1C/230 V
1
0040
4.0 A
W
0
0
0
Adjusted
m
1
0055
5.5 A
W
0
1
0
1 stage smaller
m
1
0
0
Adjusted
DRN100LS4
(50 Hz)
DRN100LM4
(60 Hz and
50/60 Hz)
0020
2.0 A
W
0
m
1
BE5A/230 V
0
0025
2.5 A
W
0
m
1
0032
3.2 A
W
0
m
1
BE2B/230 V
1
0040
4.0 A
W
0
m
1
0055
5.5 A
W
0
0
0
Adjusted
m
1
The motor cannot be started up using DIP switch S3. MOVISUITE
®
or CBG.. is required for
startup.
29129451/EN – 12/2019