7
Operation
Binary control
Operating Instructions – MOVIMOT
®
flexible
168
7.2
Binary control
The behavior of the drive unit depends on the following factors:
•
Selected configuration of the digital inputs.
•
Status of digital inputs.
The following table describes the control functions in conjunction with the predefined
configurations of the digital inputs.
The following configurations of the digital inputs are available:
No. Configuration of the digital inputs
Description
0
User-defined configuration
•
The individual digital inputs can be
configured separately.
•
The operating mode of the fixed set-
point processing can be freely con-
figured.
1
CW, CCW, setpoint changeover
•
Direction of rotation positive, nega-
tive
•
2 Speed setpoints
•
Fault reset
Fixed setpoint processing mode:
•
Mechanical setting elements
2
Enable, fixed setpoints
•
Enable
•
4 Speed setpoints
The direction of rotation is pre-
scribed by the sign of the setpoint.
•
Fault reset
Fixed setpoint processing mode:
•
Mechanical setting elements
3
Enable, external fault, setpoint
changeover
•
Positive direction of rotation (clock-
wise rotation)
•
2 Speed setpoints
•
External error input
•
Fault reset
Fixed setpoint processing mode:
•
Mechanical setting elements
4
Motor potentiometer CW
•
Positive direction of rotation (clock-
wise rotation)
•
Speed setpoint via the motor poten-
tiometer function
•
Fault reset
Fixed setpoint processing mode:
•
Mechanical setting elements
29129451/EN – 12/2019