background image

EZ VFD  CONTROL

 SERIES

5000 W. 106th Street

Zionsville, Indiana 46077

Phone (317) 873-5211

Fax (317) 873-1105

www.dartcontrols.com

Instruction Manual

EZ VFD

®

Universal AC Input 110 – 240VAC

230VAC / 3

Φ

 Output 800W

LT195 (0221)

CONTROLS

A-5-4179A

®

Содержание EZ VFD CONTROL Series

Страница 1: ...SERIES 5000 W 106th Street Zionsville Indiana 46077 Phone 317 873 5211 Fax 317 873 1105 www dartcontrols com Instruction Manual EZ VFD Universal AC Input 110 240VAC 230VAC 3Φ Output 800W LT195 0221 CONTROLS A 5 4179A ...

Страница 2: ...ely Do not attempt to operate the drive if visible damage is evident to either the circuit or to the electronic components All information contained in this manual is intended to be correct however information and data in this manual are subject to change without notice DCI makes no warranty of any kind with regard to this information or data Further DCI is not responsible for any omissions or err...

Страница 3: ...ntrol plc HMI General Features Digital Signal Processor provides digital accuracy repeatability and stability in industrial environments Single board design is more rugged and vibration tolerant than stacked multi board designs Suitable for constant and variable torque applications where the input load does not exceed 800 Watts continuous Supply Voltage x Supply Current Universal power supply acce...

Страница 4: ...Trimpot Board Factory supplied only Housing Type Open Chassis or NEMA 4X Connector Style male spade terminals for supply voltage and motor Terminal Block Torque Setting 1 95 in lb 22Nm to 2 21 in lb 25Nm Housing Material 6063 T6 Aluminum Sabic NORYL TYPE N190 Length 7 150 181 61mm Width 5 53 140 46mm Height 5 942 150 93mm Weight 3 177 lb 50 832 oz 1441 06g Operating Temperature Range 10C to 40C 14...

Страница 5: ... OUTSIDE THE RANGE OF 10o C 14o F TO 40o C 104o F ATTENTION NE MONTEZ PAS LA COMMANDE À UN EMPLACEMENT OÙ LA TEMPÉRATURE AMBIANTE SE TROUVE EN DEHORS DE LA PLAGE ALLANT DE 10o C 15o F À 40o C 104o F 7 150 5 530 5 500 455 5 125 TYP EZ VFD TM 5 394 5 942 ON OFF 0 10 4 6 8 2 CONTROLS PWR MEM FAULT Variable Frequency Drive 188 4 114 6 410 ...

Страница 6: ...ended for motor and AC supply connections Ground C NO NC P14 5K SPEEDPOT RED WHITE ORANGE P9 R Option only See P9 Terminal Hook up AC1 AC2 MOTOR W U V Note Insulated female quick connects recommended for motor and AC supply connections Ground P14 P9 C NO NC R Option only Note Insulated female quick connects recommended for motor and AC supply connections ...

Страница 7: ...eset a CL or Fault shutdown by bringing the wiper input from above 50 down to zero P9 7 LO Circuit common connection for pot LO of the 5K ohm speed pot or common return for isolated 0 5Vdc signals P9 8 COM Circuit common Logic Low connection for Run Brake and Reverse inputs P9 9 RUN This input floats Logic High must be connected via switch or jumper to P9 8 Common for drive to Run This input can a...

Страница 8: ... codes require that each hot AC Line conductor contain circuit protection Install a fuse See fusing chart below or a circuit breaker in series with each hot AC Line Do not fuse any of the motor leads For recommended fuse size see the chart below The control and motor must be wired in accordance with the National Electrical Code requirements and other local codes that may apply FUSING ADDED BY CUST...

Страница 9: ...when the master speedpot is set to zero ACCEL Trimpot The adjustable range of ACCEL is a linear 5 to 30 second ramp from 0 60Hz The ACCEL pot is factory set to approx 2 sec from 0 60Hz A CCW adjustment will reduce the ramp time and a CW adjustment will increase the ramp time Caution should be given to ACCEL ramp times below 2 sec as this may result in an over current shutdown Note Higher MAX setti...

Страница 10: ...are an indication that the system should be evaluated further by a qualified control technician BOOST Trimpot The BOOST trimpot allows the the motor to overcome sluggish response at low speed starts or high startup loads by boosting the output To increase the boost setting rotate the BOOST trimpot CW To decrease the boost setting rotate the BOOST trimpot CCW To determine if boost is required for y...

Страница 11: ...al support at sales dartcontrols com Telephone technical support at 317 873 5211 What s Special About www dartcontrols com Changes to printed material and product offerings first appear online Product manuals and other literature are easily accessible All information can be easily displayed or printed as needed Run Input Current Limit IGBT Temperature exceeded shutdown value EEPROM Corruption Rela...

Страница 12: ...873 1105 www dartcontrols com ISO9001 REGISTERED MADE IN USA productionandheadquarters facility with over 2 000 000 variable speed units in the field In addition to the standard off the shelf products you canselectfromawidevariety of options to customize controls for your specific application For further information and application assistance contactyourlocal Dart sales representative stocking dis...

Отзывы: