6
Startup
DIP switch
Operating Instructions – MOVIMOT
®
flexible
146
DIP switch S3/1: Brake type
Use this DIP switch to select the brake type of the motor.
•
OFF (S3/1 = OFF): Use this setting to select the standard brake.
This setting corresponds to the brake type that is automatically assigned to the
motor type.
1)
•
ON (S3/1 = ON): Use this setting to select the optional brake.
This setting corresponds to the brake type that is optionally assigned to the motor
type.
1)
If no brake listed in the motor selection tables
1)
matches the brake in the motor, per-
form startup of the drive train via MOVISUITE
®
. Startup via DIP switch S3 is not pos-
sible.
1) See chapter "Detailed motor selection table for startup via DIP switch S3".
DIP switch S3/2: Motor connection type
You can select the connection type of asynchronous motors at this DIP switch. When
selecting synchronous motors, the switch does not have any function.
•
OFF (S3/2 = OFF): Use this setting to select the connection type of asynchro-
nous motors
W
.
•
ON (S3/2 = ON): Use this setting to select the connection type of asynchronous
motors
m
.
If the motor connection type is changed via DIP switch S3/2, the motor connection
type via DIP switch D3/3 and S3/4 must be checked and adapted if necessary, see
chapter "Detailed motor selection table for startup via DIP switch S3".
29129451/EN – 12/2019