Service
Fault messages with parameterizable response
Operating Instructions – MOVIMOT
®
flexible
193
Fault
Description
Index
no.
Possible fault response
External synchronization
Here you can set the device re-
sponse to loss of external synchro-
nization.
8622.7
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
•
Warning with self-reset
•
Application stop (with out-
put stage inhibit) with self-
reset
•
Emergency stop (with out-
put stage inhibit) with self-
reset
•
Inhibit output stage with self
reset
Motor temperature pre-
warning – current para-
meter set
Motor temperature current para-
meter set – prewarning.
8442.5
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Electromechanical capa-
city utilization – prewarn-
ing
Here you can set the device re-
sponse to an exceeded prewarning
threshold for electromechanical ca-
pacity utilization (index 8336.2).
8622.10
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
HW limit switches – cur-
rent parameter set
8572.1
•
No response
•
Emergency stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit) with self-
reset
SW limit switches – cur-
rent parameter set
8572.2
•
No response
•
Emergency stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit) with self-
reset