8
Service
Device replacement
Operating Instructions – MOVIMOT
®
flexible
255
8.7
Device replacement
8.7.1
Notes
WARNING
Removing the electronics cover will disable DynaStop
®
.
Severe or fatal injuries.
•
If it is not permitted to deactivate the system, additional measures are required
(e.g. mechanical stake-out)
WARNING
Electric shock caused by dangerous voltages in the connection box. Dangerous
voltages can still be present for up to 5 minutes after disconnection from the power
supply system.
Severe or fatal injuries.
•
Before removing the electronics cover, de-energize the device via a suitable ex-
ternal disconnection device.
•
Secure the device against unintended re-connection of the voltage supply.
•
Secure the output shaft against rotation.
•
Wait for at least the following time before removing the electronics cover:
5 minutes
29129451/EN – 12/2019