8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
208
Subfault: 12.3
Description: Temperature
Response: Output stage inhibit
Cause
Measure
Brake temperature outside permitted range (too
high or too low).
Check the ambient conditions and the application.
Brake temperature too high. When using decent-
ralized devices, DC link overvoltage is reduced by
the brake.
Check the application for how often generator
mode occurs.
Subfault: 12.4
Description: Brake control module missing
Response: Output stage inhibit
Cause
Measure
Brake control has been activated although the
hardware is not equipped with the matching
module.
Select another brake type or brake connection
Subfault: 12.5
Description: Short circuit
Response: Output stage inhibit
Cause
Measure
Short circuit in the brake detected.
Check the brake connection.
Subfault: 12.6
Description: Wear limit reached
Response: Emergency stop + output stage inhibit
Cause
Measure
Brake worn
Replace the brake or readjust it
Subfault: 12.10
Description: Digital motor integration fault – critical
Response: Output stage inhibit
Cause
Measure
The intelligent brake rectifier of "digital motor in-
tegration" signaled a critical component fault.
See subcomponent fault
29129451/EN – 12/2019