Subfault: 25.50
Description: Runtime error – replaceable safety memory module
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Runtime error of the replaceable safety memory
module.
Contact the SEW‑EURODRIVE Service.
Subfault: 25.51
Description: Initialization error – replaceable safety memory module
Response: Warning
Cause
Measure
Initialization error of the replaceable safety
memory module.
Contact the SEW‑EURODRIVE Service.
Subfault: 25.61
Description: Failure – restore point
Response: Emergency stop + output stage inhibit
Cause
Measure
Failed to create restore point.
Delete restore point.
Subfault: 25.70
Description: Incompatible card configuration
Response: Emergency stop + output stage inhibit
Cause
Measure
The current configuration of the cards does not
match the state of the stored startup.
For example, a card was removed that was still
present during startup.
– Restore the original configuration of the cards.
– Acknowledge the fault by manual reset with
parameter set acceptance. Setting under [Diag-
nostics] > [Status] > [Fault status] parameter
"Manual fault reset".
8.6.20
Fault 26 External fault
Subfault: 26.1
Description: Terminal
Response: External fault
Cause
Measure
Error message about external error source.
Programmable via 8622.5 (default: application
stop (with output stage inhibit)).
29129451/EN – 12/2019