5
Electrical installation
Terminal assignment
Operating Instructions – MOVIMOT
®
flexible
60
Assignment
Terminal
No.
Name
Marking
Function
Connection depending on the connec-
tion unit
1)
Option /CO
2)
Option /DI
X2_A
Terminals for motor,
brake and temperature
sensor
D
Brake D
White
Connection
Brake D
Connection
Brake 14
C
Brake C
White
Connection
Brake C
Connection
Brake 13
B
Brake B
White
Connection
Brake B
Connection
Brake 15
A1
Brake A
White
Connection
Brake A
Connection
Temperature sensor
(Temp+)
T2
–
White
Reserved
Connection
Temperature sensor
(Temp-)
U
U
Gray
Motor connection, phase U
V
V
Gray
Motor connection, phase V
W
W
Gray
Motor connection, phase W
1) See chapter "Type designation of the connection unit".
2) For more information refer to chapter "Bulk cables" > "Brakemotor cables for motors with digital interface (MOVILINK
®
DDI)" > "Con-
necting the bulk cables".
The following figure shows the factory-installed jumpers at the X9 terminals:
1
2
3
4
11 12 13 14
21 22 23 24
5
6
15 16
25 26
X9
29006177419
These jumpers are not present in the following designs:
•
Designs with plug connectors with STO function.
For additional information, refer to chapter "Functional safety".