Startup
Control elements
Operating Instructions – MOVIMOT
®
flexible
139
6.4.2
Potentiometer f1
NOTICE
Loss of the ensured degree of protection if the screw plug of the potentiometer is not
installed or not installed correctly.
Damage to the device.
•
After setting the setpoint, make sure the screw plug of the potentiometer has a
seal and screw it in.
Use the f1 potentiometer to adjust speed setpoint f1.
•
When the device is set to Easy mode, the predefined setpoint is always active at
the potentiometer f1.
•
The potentiometer f1 can be deactivated in Expert mode. In this case, the para-
meterizable replacement value is activated as speed setpoint f1.
The following figure shows how to scale the speed setpoint f1 using potentiometer f1:
100
1
0
2
3
4
5
6
7
8
9
10
75
25
50
6
5
f1
Potentiometer setting
Speed setpoint f1
Application limit
1)
%
29011977739
1)
Depending on the selected direction of rotation, the parameter
Application limit –
positive speed
or the parameter
Application limit – negative speed
are used to
scale the speed setpoint f1.
For the application limit, refer to the MOVISUITE
®
parameter tree in the following
menu:
Functions
>
Monitoring functions
>
Limit values
>
Application limit
.
29129451/EN – 12/2019