56
Operations Switched PDU
Installation and Operations Manual
Administrative Command Summ
ary (continued…)
Set Tower 3Phase
Specifies the AC voltage type for the tower
Set Tower Model
Specifies the model number for the tower
Set Tower Name
Specifies a descriptive field for the tower
Set Tower ProdSN
Specifies the serial number for the tower
Set Tower
Specifies the AC or DC voltage type for the tower
Set UPS AddInfeed
Adds an infeed association to a UPS
Set UPS DelInfeed
Deletes an infeed association from a UPS
Set UPS GETComm
Sets the UPS ‘get’ community string
Set UPS Host
Sets the UPS Host IP address or hostname
Set UPS Port
Specifies the target port for a UPS
Set UPS Type
Sets the UPS type
Set UPS VPoll
Enables or disables UPS voltage polling
Set User Access
Sets the access level for a user
Set User Envmon
Grants or removes user access to environmental monitoring
Set User Password
Changes the password for a user
Show EnergyWise
Displays Cisco EnergyWise network configuration information
Show FTP
Displays FTP configuration information
Show Infeeds
Displays infeed configuration information
Show Network
Displays network configuration information for all IPv4 and IPv6 settings
Show Options
Displays system option information
Show Outlets
Displays configuration information for all outlets
Show Ports
Displays serial/Pass-Thru port configuration information
Show SNTP
Displays SNTP configuration information
Show System
Displays system configuration information
Show System Status
Displays system power and tower configuration information
Show Towers
Displays tower configuration information
Show UPS
Displays UPS configuration information
Version
Displays the firmware version
To display the names of commands that you can execute:
At the command prompt, press
Enter
. A list of valid commands for the current user appears.
Operations Commands
Operations commands manage outlet states, provide information about the environment of the unit, and control
session operations.
Turning outlets on:
The On command turns on one or more outlets. When the command completes, a display indicating all outlets
affected and their current states will be displayed.
To turn outlets on:
At the Switched CDU: prompt, type
on
, followed by an outlet name, and press
Enter
, or
Type
on
, followed by a group name, and press
Enter
, or type
on all
and press
Enter
.
Examples
The following command turns the second outlet on, using the outlet’s absolute name:
Switched CDU: on .a2<Enter>
The following command turns on all the outlets in the group named ServerGroup_1:
Switched CDU: on ServerGroup_1<Enter>