![Server Technology Switched Rack PDU Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/server-technology/switched-rack-pdu/switched-rack-pdu_installation-and-operation-manual_1246861054.webp)
54
Operations Switched PDU
Installation and Operations Manual
Administrative Command Summary
Create User
Adds a user account
Delete Groupfromuser
Removes access to one or more groups for a user
Delete Outletfromgroup
Deletes an outlet from a group name
Delete Outletfromuser
Removes access to one or all outlets for a user
Delete Portfromuser
Removes access to one or all serial/Pass-Thru ports
List User
Displays all accessible outlets/groups/ports for a user
List Users
Displays privilege levels for all users
Remove Group
Deletes a group name
Remove UPS
Deletes a UPS association
Remove User
Deletes a user account
Restart
Performs a warm boot
Set Banner
Set the pre-login banner text
Set Bluetooth Discover
Determines the current status of the pushbutton on the Bluetooth module
Set Bluetooth Name
Configures the name of the discovered Bluetooth module on the Android device
Set Bluetooth Pincode
Pin code value for legacy Bluetooth modules that require a pin to pair the module
Set Bluetooth Transpwr
Designated transmission power (dbm) for the Bluetooth module.
Set DHCP
Enables or disables DHCP support
Set DHCP Boot Delay
Enables or disables a 100-second boot delay between PDU and DHCP server
Set DHCP Static Address Fallback Enables or disables DHCP fallback to a static IP address
Set DNS
Sets the IP address of the Domain Name server
Set EnergyWise
Enables or disables the Cisco EnergyWise network
Set EnergyWise Domain
Sets the Cisco EnergyWise domain name
Set EnergyWise Port
Sets the Cisco EnergyWise port number
Set EnergyWise Refresh
Rate (in seconds) at which information is pushed to the EnergyWise manager
Set EnergyWise Secret
Sets the Cisco EnergyWise secret
Set Envmon Name
Specifies a descriptive field fro the integrated Environmental Monitor
Set Envmon THS Name
Specifies a descriptive field for a temperature-humidity sensor
Set FTP Autoupdate Day
Sets the automatic FTP update day
Set FTP Autoupdate Hour
Sets the automatic FTP update hour
Set FTP Autoupdate
Enables or disables automatic FTP update support
Set FTP Directory
Specifies the directory for the file to be uploaded
Set FTP Filename
Specifies the file to be uploaded via FTP
Set FTP Host
Sets the FTP Host IP address or hostname
Set FTP Password
Sets the password for the FTP Host
Set FTP Test
Validates that the PDU can login to the FTP server and verify/download the firmware file
Set FTP Server
Enables or disables the FTP server
Set FTP Username
Sets the username for the FTP Host
Set Gateway
Sets the gateway of the PDU
Set HTTP
Enables or disables HTTP access and sets the HTTP target port.
Set HTTP Port
Specifies the target port for HTTP access
Set Infeed Loadmax
Specifies the maximum load capacity for the infeed
Set Infeed Name
Specifies a descriptive field for the infeed
Set Infeed Voltage
Specifies the nominal input voltage for the infeed
Set IP Address
Sets the IP address of the PDU
Set LDAP UseTLS
Enables or disables LDAP over TLS/SSL support