14 ACU-220
SATEL
Outputs
See “Outputs indicating problems in the ABAX 2 system” p. 7.
NO/NC
– output type. You can select NO (normally open) or NC (normally closed). Click
twice on the field to change the type.
Programmable outputs
See “Programmable outputs” p. 8.
NO/NC
– output type. You can select NO (normally open) or NC (normally closed). Click
twice on the field to change the type.
Operating time
– the time during which the output is turned on. Operating time shorter than
2 minutes can be programmed to 1 second accuracy. A longer operating time is rounded
up to full minutes.
No automatic update of wireless devices firmware
– if this option is enabled, firmware of
the wireless devices registered to the controller is not updated automatically (see
“Updating the firmware of ABAX 2 wireless devices” p. 54).
5.4 Devices
Fig. 11. ABAX 2 Soft program: “Devices” tab.
Name
– individual device name (up to 16 characters). You can enter a name that will make it
easier to figure out the location or intended purpose of the device.
S/N
– serial number of the device.
Type
– type of the wireless device. If the device takes up more than 1 position on the list, the
“^” character is displayed in consecutive positions.
Output
– controller output indicating the device status (see “Programmable outputs” p. 8). In
the column, you can enter the number of output from 1 to 8.
Input
– controller input for the control of wireless device (see “Control inputs” p. 7). In the
column, you can enter the number of input (from 1 to 4) or letter “z” (detector always
active). The “Always active” option is available for most wireless detectors. It enables the
detector to be switched into the active mode permanently (see “Wireless detectors” p. 47).
ARU
– parameter available for the wireless device, if the ARU-200 radio signal repeater is
registered to the controller. It defines whether the device is to communicate with the
controller directly or via the selected ARU-200 radio signal repeater (a few ARU-200 radio