SATEL ACU-220
37
APD-100 (APD-200 Pet)
Enter 2 digits:
1st digit – sensitivity: 1 (low), 2 (medium) or 3 (high),
2nd digit – pet immunity option – 0 or 1 (the entered value is irrelevant).
APMD-150 (APMD-250)
Enter 3 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3rd digit – the way of operation in the test mode: 0 (alarm after motion is detected by both
sensors), 1 (alarm after motion is detected by PIR sensor) or 2 (alarm after motion is
detected by microwave sensor).
ARD-100 (ARD-200)
Enter a number from the 1 to 16 range to determine sensitivity (1 – minimum; 16 –
maximum).
ASD-150 (ASD-250)
Enter 2 digits:
1st digit – option to signal alarm from other ASD-250 detectors: 0 (disabled) or 1 (enabled).
2nd digit – option to send out alarm to other ASD-250 detectors: 0 (disabled) or 1 (enabled).
ATD-100 (ATD-200)
For each position taken by the detector, enter in turn:
letter H (high temperature threshold) or L (low temperature threshold),
number from a range of -30 to +70 (with 0.5 accuracy) to define temperature,
number from a range of 0.5 to 10 (with 0.5 accuracy) to define tolerance.
AVD-100 (AVD-200)
Magnetic contact – do not configure.
Shock detector – enter 2 digits:
1st digit – sensitivity: from 1 to 8 (1 – minimum ; 8 – maximum).
2nd digit – the number of shocks – the entered value is irrelevant.
ASP-100 (ASP-200)
Enter 2 digits:
1st digit – type of acoustic signaling: from 1 to 4 – see table 5.
2nd digit – maximum duration of signaling: 1 (1 minute), 2 (3 minutes), 3 (6 minutes) or 4
(9 minutes).
1
Two sound frequencies (1450 Hz/2000 Hz) alternating within
1 second.
2
Sound with rising frequency (from 1450 Hz to 2000 Hz) within
1 second.
3
Sound with smoothly rising and falling frequency (1450 Hz –
2000 Hz – 1450 Hz) within 1 second.
4
Sound with falling frequency (from 2000 Hz to 1450 Hz) within
1 second.
Table 5. Types of acoustic signaling available in the ASP-200 siren.