48 ACU-220
SATEL
8.2.2.3 Wireless expanders of hardwired zones and outputs
The controller input to which the expander output is assigned controls the operation of that
output. The controller output to which the expander zone is assigned, indicates the state of
that zone.
Information on the state of inputs and commands to change the state of outputs are sent
immediately. The zone settings are sent during periodical communication.
If communication with the controller is lost, all previously activated outputs will be
deactivated after 20 communication periods.
If the ACX-220 expander is powered from a power supply unit connected to the APS
connector, the information about power supply trouble presented in the ABAX 2 Soft program
has the following meaning:
first position – power supply overload,
second position – low battery,
third position – AC mains loss.
8.2.2.4 Wireless 230 V AC controllers
Activation of the input to which the controller is assigned turns on the relay controlling the
230 V AC circuit (turns on power).
The output to which the wireless controller is assigned is turned on when the relay controlling
the 230 V AC circuit is activated [operating modes 1 and 2] / ASW-200 controller button is
pressed [operating mode 0] / ASW-210 controller input is activated [operating mode 0].
8.2.2.5 Radio signal repeater
The output to which the first position of the radio signal repeater is assigned is turned on in
the event of 230 V AC mains loss.
The output to which the second position of the radio signal repeater is assigned is turned on
in the event of a battery trouble.
9
APT-200 keyfobs
If the controller works as expander of wireless devices for SATEL alarm control panels, the
number of supported keyfobs depends on the number of control panel users. When the
controller works as universal module of wireless devices, it can support up to 256 keyfobs.
Before adding a keyfob that was previously registered to the ABAX / ABAX 2 system,
you must restart it (to do so, long press the
and
buttons for 30 seconds or
remove the battery for 30 seconds).
9.1 Expander of wireless devices for SATEL alarm control panels
The data related to keyfobs are stored in the controller. After the controller containing
keyfob data is connected to the control panel, keyfobs will be automatically assigned
to the existing users.
9.1.1 Keyfobs in the INTEGRA / INTEGRA Plus system
If two or more ABAX / ABAX 2 controllers are connected to the control panel, the keyfob will
be supported by all of them. The keyfobs data are written automatically to all the controllers.