Fig. 21. DLOADX
program: parameters and options of the controller connected to VERSA /
VERSA Plus / VERSA IP control panel.
8.1.2 Functions
Test mode
– to carry out diagnostics / service work, you can start the test mode in the
ABAX 2 system. When the system is running in the test mode:
– detector LEDs are enabled,
– tamper signaling in the sirens is blocked.
The command to start/end the test mode is sent during periodical communication, i.e. with
delay whose duration depends on the frequency of periodical communication. The test
mode will be disabled automatically 30 minutes after:
– starting the test mode from the DLOADX program (the countdown of 30 minutes runs
from exiting the controller settings),
– exiting the service mode in the INTEGRA / INTEGRA Plus / VERSA / VERSA Plus /
VERSA IP control panel,
– closing the ABAX 2 Soft program.
As required by EN50131, the level of radio signal sent by wireless devices is lowered
when the system is running in the test mode.
Synchronize
– the function does not apply to the ABAX 2 system.
8.1.3 Device settings
ARU
[Use ARU-100] – parameter available for a wireless device, if the ARU-200 repeater is
registered in the controller (the controller is connected to the INTEGRA or INTEGRA Plus
control panel). It allows you to define whether the device is to communicate to the
controller directly, or via the selected ARU-200 repeater (several ARU-200 repeaters can
be registered in the controller).
Always active
[Active mode] – the option is available for the most of wireless detectors. If
enabled, the detector is permanently switched over to the active mode (see „Wireless
detectors” p. 42).
The wireless detectors assigned to 24-h zones are always in the active mode,
therefore the “Always active” option does not have to be enabled for them.