6. When the prompt is displayed asking you whether to continue the firmware update, click
“Yes”. The controller firmware will be updated.
10.1 Updating the firmware of ABAX 2 wireless devices
During the controller firmware update, programs enabling the update of the firmware of
ABAX 2 system devices are also saved to the controller memory. If devices with outdated
versions of firmware are registered in the controller, their firmware is updated by the
controller automatically. The process of verification of the firmware of registered devices is
run after each controller firmware update, as well as after adding new devices.
If attempts to automatically update the firmware of devices fail (e.g. as a result of radio signal
interference or problems with the device power supply), the
icon will be displayed in the
ABAX 2 Soft program at the device firmware version. You can then click on the
button
(see “Devices status” p. 16 and “Keyfob state” p. 20) to restart the update process.
At the final phase of the firmware update, the device does not perform its normal
functions for a few seconds.
If you do not want the controller to automatically update the firmware of the devices
registered in it, enable the “No automatic update of wireless devices firmware” option
in the controller.
11 Restoring the controller factory settings
1. Power off the controller.
2. If wires are connected to the controller communication bus, disconnect them.
3. Short together the terminals CKE and DTE.
4. Power on the controller. The LED indicating the status of communication with the control
panel will start blinking.
5. When the factory default settings are restored, the LED will go off for a while and then it
will go on with steady light.
6. Open the terminals CKE and DTE.
7. Power off the controller.
8. Reconnect the wires to the controller communication bus.
9. Power on the controller.
12 Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) .......................................................... up to 2000 m
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ..........................................................................................75 mA
Maximum current consumption ......................................................................................100 mA
OC type outputs .............................................................................................. 50 mA / 12 V DC
Security grade according to EN50131-3 ....................................................................... Grade 2
Complied with standards. EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-3, EN 50131-5-3
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range...............................................................................-10°C...+55°C