16 ACU-220
SATEL
Fig. 12. ABAX 2 Soft program: “Status” tab.
Power supply
Information about current voltage of the controller power supply.
DIP-switches
Graphic information about setting of DIP-switches.
Outputs
Information about the state of controller outputs:
[blank] – output in normal state.
[red] – output active.
Devices status
Name
– individual device name.
Type
– device type. If the device takes up more than 1 position on the list, the “^” character is
displayed in successive positions.
S/N
– serial number of the device.
Act.
–
[green] icon indicates that:
detector: working in active mode,
another device: running.
State
–
[red] icon indicates that:
detector: alarm,
siren: signaling triggered,
expander of wired zones/outputs: input activated,
ASW-200 controller: button pressed / relay turned on (230 V AC power ON),
ASW-210 controller: input activated / relay turned on (230 V AC power ON).
TMP
– tamper information:
[red] – tamper,