SATEL ACU-220
45
L
– low (when the temperature drops below the defined value, alarm will be triggered).
Temperature
– enter a number from a range of -30 to +70 (with 0.5 accuracy) to define
temperature.
Tolerance
– enter a number from a range of 0.5 to 10 (with 0.5 accuracy) to define
tolerance.
AGD-200
– wireless glass-break detector. You can configure:
Sensitivity
– select low, medium or high.
AMD-202
– wireless magnetic contact with input for roller shutter detector. For the roller
shutter input, you can configure:
Pulses number
– select the number of pulses after which the roller shutter input will
trigger alarm. You can select a number from a range of 1 to 8.
Counting time
– select the time period during which the defined number of pulses must
occur for the roller shutter input to trigger alarm. You can select 30 seconds,
120 seconds, 240 seconds or “---“ (unlimited duration).
AOCD-260
– wireless outdoor dual technology curtain detector. You can configure:
PIR sensitivity
– select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity
– select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
AOD-210
– wireless outdoor dual technology motion detector. You can configure:
PIR sensitivity
– select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity
– select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
Dusk det. sensitivity
– select a number from a range of 1 to 4 (1 – minimum; 4 –
maximum).
APD-200
– wireless passive infrared detector. You can configure:
Sensitivity
– select low, medium or high.
APD-200 Pet
– wireless passive infrared detector with pet immunity up to 20 kg. You can
configure:
Sensitivity
– select low, medium or high.
APMD-250
– wireless dual technology detector. You can configure:
PIR sensitivity
– select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity
– select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
Test mode
– select how the detector should work in the test mode:
PIR & MW
– alarm after motion is detected by both sensors,
PIR
– alarm after motion is detected by PIR sensor,
MW
– alarm after motion is detected by microwave sensor.
ARD-200
– wireless reorientation detector. You can configure:
Sensitivity
– select a number from a range of 1 to 16 (1 – minimum; 16 – maximum).
ASD-250
– wireless smoke detector. You can configure:
Alarm from other detectors
– enable the option if the detector is to signal alarm from
other ASD-250 detectors.
Alarm propagation
– enable the option if the detector is to send alarm to other ASD-250
detectors.
ATD-200
– wireless temperature detector. For both positions occupied by the detector, you
can configure:
Temperature threshold
– select the threshold type:
H
– high (when the temperature rises above the defined value, alarm will be triggered),
L
– low (when the temperature drops below the defined value, alarm will be triggered).