10 ACU-220
SATEL
8. Using screws, install the electronics board in the enclosure.
4.4 Setting DIP switches
Using the DIP switches (see “DIP-switches” p. 5):
1. Define the controller operating mode (switches 9 and 10).
2. Select the transmitting antenna (switch 8).
3. Set the controller's address if the controller is to be connected to the INTEGRA /
INTEGRA Plus control panel (switches 1-5).
4.5 Connecting the wires
Protect the wiring against contact with sharp edges or else they can damage the
insulation of cables.
4.5.1 Expander of wireless devices for SATEL alarm control panels
Depending on the control panel to which the controller is to be connected:
INTEGRA / INTEGRA Plus
: connect the CKM, DTM, CKE, DTE and COM terminals to the
corresponding terminals of the control panel communication buses (Fig. 6).
Fig. 6. Method of connecting the controller to the INTEGRA / INTEGRA Plus control panel.
VERSA / VERSA Plus / VERSA IP
: connect the CKE, DTE and COM terminals to the
corresponding terminals of the control panel communication bus (Fig. 7).
Fig. 7. Method of connecting the controller to the VERSA / VERSA Plus / VERSA IP control
panel.