RVision P/N
660904-01
Rev 1
C-
1
Appendix C – Operational Specifications
The system physical, environmental and mechanical specifications are detailed in the
following table.
System Environment
Operating temperature
+5
o
F to +140
o
F / -20
o
to +70
o
C
Vibration and shock
3grms 3axis, Random, 5 to 1000Hz
System Metrics
Size
6.73”W x 7.81”H, 18cm diameter, 20cm tall
Weight
9.04 lbs (4.1 kg)
System Power
Operating Voltage
12 to 30 VDC, 500 ma, 2A peak
Command and Control
RS232/RS422; IP optional
Factory configured/software selectable
BAUD 2400; 4800; 9600; 57,600
Software Selectable/Factory
Configured to 9600 Baud (unless otherwise
requested)
Pan
Pan Angle Range
440
o
Max Pan Speed
135
o
/second
Pan Angle Encoder Resolution
0.5
o
Tilt
Tilt Angle Range
240º
Max Tilt Speed
50
o
/second
Tilt Angle Feedback Resolution
0.5
o
Tilt Mean Time between
Failures
5 years or 2,500,000 movements
Cable Connection (base)
Video Connector
QuickConnect
TM
standard
Video Switch
Optional