Setup and Operations Manual
Page 30
RVision P/N 660904-01 Rev 1
Changing the Cameras Baud Rate
Cameras shipped from RVision are set to 9600 bps, unless a different baud rate is
requested at time of purchase.
To change the baud rate, go to the Manual Commands tab and select the baud rate
from the List pull down menu and then click Send.
Figure 35: Changing Baud Rate
Changing the Camera ID
To change the cameras ID (factory default is set to 1) using the Send Command field
in the Manual Commands tab page enter the following command:
88 30 AB FF
where AB is the hexadecimal camera address.
As an example, to set the camera ID to 24 the AB parameter is hexadecimal 18.
88 30 18 FF
NOTE: Camera ID 08 is reserved for the system. ID 0 is not allowed.
Contact RVision support at
for document P/N
660032 – Camera API which list the supported commands.