9.7.5 Further supervisions
Runtime supervision.
A runtime supervision can be activated with this,
i.e. the unit switches off and the relevant fault signal is displayed if the set
driving time is exceeded. The minimum running time is 20 sec.; at smaller
values, the runtime supervision is deactivated and 0 is displayed.
The
monitoring function of the drive contactors
is activated here
insofar as an appropriate digital input has been configured with this
function (see
Section 9.7.4.2.2
).
The monitoring of the brake is activated here (s.
Section 9.7.4.2.3
).
The monitoring of the motor-PTC is activated here.
Durch Eingabe einer "1" wird die
Überwachungsfunktion für die
Bremskontakte der Antriebsbremse aktiviert
(siehe
Abschnitt
9.7.4.2.4
)
.
Extended
Monitorings
----------------------
Monitorings
Run-Time 0
----------------------
Monitorings
Contactor 0
----------------------
Monitorings
Brake Start 0
----------------------
Motitorings
PTC Motor 0
----------------------
○
Motitorings
BrakeMon.EN81 0
----------------------
○