2.4 Installation of the Brake Resistor
Important note !
Due to the heat dissipation the brake resistor should always be fixed in the range of non-flammable
bases. Above the brake resistor there must not be any inflammable objects. This is particularly
important if devices with integrated brake resistor are installed.
For proper ventilation there should be
at least 50 cm
space above and below the brake resistor.
The brake resistor must be mounted in such a way, that the cable exit is on a side.
If the above mentioned recommendations are not considered, FIRE RISK exists !
It is recommended, to brake resistor with integrated temperature monitoring. These are optionally
available at RST.
For this, please refer to the following wiring diagram.
ϑ
ϑ
ϑ
ϑ
b
rw
_
u
e
b
2
.s
kd
25 (DigIn 2)
20 (+24V)
+
RB
PE
In the case of devices with integrated brake resistor as well as external brake resistors with
permissible ON-times > 20% or a higher power, this monitoring function is already included as a
standard. For details, refer to
Chapter 4.2.1.5
.
Содержание FRC-F Series
Страница 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Страница 16: ...9 581 140 6 Page 16...
Страница 17: ...9 581 140 6 Page 17...
Страница 23: ...9 581 140 6 Page 23...
Страница 85: ...9 581 140 6 Page 85...
Страница 90: ...9 581 140 6 Page 90...
Страница 122: ...9 581 140 6 Page 122...
Страница 123: ...9 581 140 6 Page 123...
Страница 124: ...9 581 140 6 Page 124...
Страница 125: ...9 581 140 6 Page 125...