9.581.140-6
Page:
61
Proportional coefficient of the stillstand controller.
Integration time of the stillstand controller.
Switch-over threshold for speed regulator amplification
Increase of starting regulator's gain in refer to the speed regulator
Increase of stopping regulator's gain in refer to the speed regulator
Torque pre-control during acceleration and deceleration. Overshooting
and undershooting after the ramps can be eliminated with this parameter.
Control Settings
Halte P 60
----------------------
○
Control Settings
Halte I 250
----------------------
○
Control Settings
GA 50 rpm
----------------------
○
Control Settings
K START 100 %
----------------------
○
Control Settings
K STOP 100 %
----------------------
○
Control Settings
MV 100
----------------------
○