![RST FRC-F Series Скачать руководство пользователя страница 136](http://html1.mh-extra.com/html/rst/frc-f-series/frc-f-series_manual_1496813136.webp)
9.581.140-6
Page:
136
15.1.37 GS failure during travel
Triggered:
During the travel operation, the GS signal failed. GS is not monitored, at V0, VN and V1.
Causes and remedy:
Interruption of safety circuit, emergency shut-down by controller
15.1.38 EEPROM
Triggered:
Error of internal memory module
Triggered:
Replace circuit board
15.1.39 Timeout Brake Start
Triggered:
If brake controller is activated and no feedback on opening of the brake is received within 5 seconds
after actuation of the ZB relay.
Causes and remedy:
Check brake, check wiring.
15.1.40
STO failure during travel
Triggered:
In converter operation without travel contactors, the STO enable signals disappeared during a travel
operation.
Causes and remedy:
Brief interruption of safety circuit, check wiring.
15.1.41
STO logic
Triggered:
During converter operation without travel contactors, the STO monitoring logic monitor was triggered.
STO1 and STO2 signals have different levels.
Causes and remedy:
Check wiring.
15.1.42 Brake-On EN81
Triggered:
The monitoring of the brake contacts has responded. Either it is already one of the signals before
driving or lack a signal after each ride.
Causes and remedy:
Inspection of the wiring and the microswitch.
15.1.43 Brake-Off EN81
Triggered:
Die Überwachung der Bremskontakte hat angesprochen. Nach Fahrtende wechseln die Eingänge
nicht auf 0 V.
Causes and remedy:
Inspection of the wiring and the microswitch.
Содержание FRC-F Series
Страница 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Страница 16: ...9 581 140 6 Page 16...
Страница 17: ...9 581 140 6 Page 17...
Страница 23: ...9 581 140 6 Page 23...
Страница 85: ...9 581 140 6 Page 85...
Страница 90: ...9 581 140 6 Page 90...
Страница 122: ...9 581 140 6 Page 122...
Страница 123: ...9 581 140 6 Page 123...
Страница 124: ...9 581 140 6 Page 124...
Страница 125: ...9 581 140 6 Page 125...