![RST FRC-F Series Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/rst/frc-f-series/frc-f-series_manual_1496813078.webp)
9.581.140-6
Page:
78
9.7.4.3 Drive Commands
9.7.4.3.1 Encoding
Here, you can select between parallel and binary encoding of the drive
commands
Parallel encoding (standard).
Binary encoding.
For binary encoding of the drive commands, controller inputs V1, V2, V3, V4 are used. The
assignment is as follows:
Drive Speed
VVVF
term. 16
(V1)
term. 17
(V2)
term. 18
(V3)
term.19
(V4)
remark
STOP
0
0
0
0
V0
1
0
0
0
creep speed
V1
0
1
0
0
inspection
V31
1
1
0
0
intermediate speed
VN
0
0
1
0
fine levelling
V0
1
0
1
0
creep speed
V32
0
1
1
0
intermediate speed
V33
1
1
1
0
intermediate speed
V2
0
0
0
1
1 st intermediate speed
V3
1
0
0
1
2 nd intermediate speed
V4
0
1
0
1
high speed
9.7.4.3.2 Configuration of direction signals
Here, the VVVF controller can be configured for operation with only one
direction signal. To do this, the parameter must be set to 1.
9.7.4.4 Outputs
Here the function of the VVVF outputs can be configured
By setting a 1 the inverter signals the magnetized motor by the relay ZS
(s. chapter
5.2.2.3.4
)
.
Drive Commands
Parallel
----------------------
Drive Commands
Parallel
----------------------
Drive Commands
Binary
----------------------
Drive Commands
OnlyRO1) 0
----------------------
Inputs/Outputs
Outputs
----------------------
Outputs
ZS=Imot 1
----------------------
Содержание FRC-F Series
Страница 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Страница 16: ...9 581 140 6 Page 16...
Страница 17: ...9 581 140 6 Page 17...
Страница 23: ...9 581 140 6 Page 23...
Страница 85: ...9 581 140 6 Page 85...
Страница 90: ...9 581 140 6 Page 90...
Страница 122: ...9 581 140 6 Page 122...
Страница 123: ...9 581 140 6 Page 123...
Страница 124: ...9 581 140 6 Page 124...
Страница 125: ...9 581 140 6 Page 125...