8.5 Setting of the load application
Experience has shown that a satisfactory load application at the moment of brake release can be
achieved with the factory setting. If in some cases a jerk occurs, the following shall be done:
•
Make sure that the timing of the control signals (drive commands) is correct.
When starting, this means that the brake must be fully open before the setpoint start begins. In
case of doubt, this can be achieved by increasing the SF parameter in the Settings - Times /
Distances menu.
When stopping, the control signals and the driving contactors must not be switched off until the
drive has been driven electrically to 0 and the inverter output stage is switched off. This is signaled
via the output ZS.
•
In the Extended – Control Settings menu, increase the
LR Start
parameter. Press the "E" and "C"
buttons simultaneously for 1 second to unlock this parameter.
•
In the menu Setting – Control Settings, reduce the
Halte I
parameter.
•
In the menu Setting – Control Settings, increase the
Halte P
parameter.
•
In the menu Extended - Inputs/Outputs - Encoder/Motor, reduce parameter
T-1
Hints:
As the step width for the parameter changes, approximately 10% of the preset standard value should
be selected.
Each of the above measures must be carried out individually. If this does not improve, please reset the
original value before proceeding to the next step.
Содержание FRC-F Series
Страница 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Страница 16: ...9 581 140 6 Page 16...
Страница 17: ...9 581 140 6 Page 17...
Страница 23: ...9 581 140 6 Page 23...
Страница 85: ...9 581 140 6 Page 85...
Страница 90: ...9 581 140 6 Page 90...
Страница 122: ...9 581 140 6 Page 122...
Страница 123: ...9 581 140 6 Page 123...
Страница 124: ...9 581 140 6 Page 124...
Страница 125: ...9 581 140 6 Page 125...