26
Water and Milk Connection
4.6 Water and Milk Connection
Water connection
Milk connection
4.6.1 Water Connection
:
Connect the 1/2“ water hose to the 3/4“ hose coupling at the right of the automatic
feeder.
The water pressure supplied by the customer has to be between 2.5 and 6 bar.
Note
: To ensure troublefree functioning of the automatic feeder, take care that the water
pressure does not fall below 2.5 bar!
Take care that there is no pressure variation of the water pipe.
In case of water pipes with small cross section it may happen that, in the feeding mode or
when water is taken out of the same pipe simultaneously, the water pressure will drop.
If the water pressure is below 2.5 bar you have to use a water tank.
Install an additional water valve.
The pressure reducer is factory--set to 1.5 bar.
Do not alter the setting of the pressure reducer!
If you do not observe the above--mentioned notes, there is no guarantee that the
automatic feeder will run trouble--free!