157
Accessories
20 Accessories
20.1 Two--Group--Valve--Unit
Thanks to the priority control with two--group--valve--unit, the automatic feeder can provide,
in succession, two feeding stations with milk, i.e. as soon as an entitled animal enters the
feeding station the available milk amount for this animal will be distributed without inter-
ruption while the other feeding station is blocked during this time. Change--over to the other
feeding station takes place via the two--group--valve--unit located in the left interior of the
automatic feeder.
The milk hose leads from the mixer to the feeding pump and from there to the solenoid val-
ves. If you open the lateral left door, you will find the connections from the box valves to
the teat at the front side of the corresponding solenoid valves. The milk is conveyed to the
corresponding feeding stations via the suction hoses. The hose connection from the mixer
outlet valve to the teat is located below the outlet valve. The liquid in the mixer jar is con-
veyed to the outside via the suction hose that runs through an opening in the chassis of the
automatic feeder.
Mixer outlet valve
Suction hose connection 1
Suction hose connection 2
Feeding pump
Suction hose connection mixer
Box valve 1
Hose connection mixer
outlet valve
Box valve 2
Make sure that suction hose connection 1 leads to feeding station 1 (antenna 1) and suction
hose connection 2 to feeding station 2 (antenna 2). If you do not observe this order, the an-
imal that claims its milk portion at feeding station 1 will get no milk because the milk por-
tion will be dispensed at feeding station 2 instead.