D
Annex
delivered once again into the mixer jar via the coil and is drained off again via the mixer
outlet valve. Finally the mixer jar is rinsed by a 500 ml water portion that is subsequently
pumped out.
During the pre--cleaning process, the display shows:
Main cleaning
During the main cleaning process, 1.25 liters of water and --
in case the automatic feeder is equipped with a detergent do-
sing pump that has been previously selected in Setup -- some
detergent are delivered into the mixer jar. The water starts
circulating. The display shows:
Time starts running backwards from 10 to 0 minutes. Press
Start/Stop to cut off the cleaning process at any time.
After 10 minutes have lapsed, the liquid in the mixer jar is
pumped out via the mixer outlet valve. The following mes-
sage is displayed:
Rinsing
The rinsing process starts running in order to be sure that there is no detergent in the coil of
the heat exchanger anymore. 800 ml of water are delivered automatically from the coil into
the mixer jar and are then pumped out via the mixer outlet valve. The mixer is then rinsed
by 500 ml of water that are subsequently drained off. The coil is rinsed for 5 seconds by
800 ml of water, i.e. the water in the mixer jar circulates to the coil and is pumped out im-
mediately afterwards. Now 1 liter of water is delivered once again from the coil into the
mixer jar and is drained off again via the mixer outlet valve. Finally the mixer jar is rinsed
by a 500 ml water portion. This water is subsequently pumped out, too.
During the rinsing process the display shows:
The electrodes and valves are checked automatically. 1.5 li-
ters of water are delivered into the mixer jar where they are
stirred for 20 seconds. After that, they are drained off via the
mixer outlet valve. This process should remove all residual
foam inside the mixer jar.
After heat exchanger cleaning has been completed, the coil is filled with water. If an entitled
animal enters the feeding station, the water portion in the heat exchanger will be delivered
into the mixer jar and drained off via the mixer outlet valve. Only then a milk portion starts
to be prepared.
Turn the program switch to position „Feeding Mode“, in order to go back to feeding mode.
Notes on automatic heat exchanger cleaning (time--controlled)
If the electrode is covered, automatic heat exchanger cleaning will be deferred for 1 hour at
most so that an animal has the opportunity to drink up the liquid in the mixer jar. If the an-
imal does not drink up the liquid within this time (the electrode is still covered), the liquid
will be drained off via the mixer outlet valve and the cleaning cycle starts running.
pre-rinse HE
clean HE
clean HE
rem.:10:00min stop?
clean HE
emptying mixer