137
Cleaning
:
If the milk hose has to be rinsed too, connect it to the quick coupling of the cleaning
adaptor.
As soon as the suction hoses are ready for cleaning, press EN-
TER to confirm „yes“ in order to activate the cleaning cycle
(see annex)
.
Pre--cleaning starts running. In support of the cleaning pro-
cess, push the button at the upper left of the chassis to activate
the feeding pump.
The display shows:
The next water portion is dispensed as soon as the long electrode is free.
After all milk rests have been removed from the system and
clear water comes out of the hoses, press Start/Stop to com-
plete pre--cleaning. The display shows:
Now connect the cleaning adaptor or the milk hose connected
to it to the milk supply. Press ENTER to confirm „yes“.
The following message is displayed:
In support of the deaeration process, push the button at the
upper left of the chassis to activate the feeding pump.
As soon as the system is deaerated, the main cleaning process (lasting 10 minutes) starts
running automatically. If the detergent dosing pump is available and you activated it in Se-
tup, the detergent will be automatically added to the water.
Time starts running backwards from 10 to 0 minutes. You can
cut off the cleaning process at any time by pressing Start/
Stop.
After the main cleaning process has been completed you have
to remove the suction hoses from the milk supply of the auto-
matic feeder in order to start the rinsing process.
After you have removed the hoses, press ENTER to confirm
„yes“.
The following message appears:
In support of the rinsing process, push the button at the upper left of the chassis to activate
the feeding pump. The rinsing water is then drained via the mixer jar and the connected ho-
ses. As soon as the long electrode (level electrode) is free, the next water portion will be
dispensed from the stainless steel coil.
After all detergent rests have been removed, press Start/Stop
to complete the rinsing process. The display shows:
hoses
ready ?
yes
press feeding pump
prerinse ?
stop
hoses
connected ?
yes
to deaerate
press feeding pump
clean HE
rem.:09:55min stop?
hoses
uncoupled
yes
press feeding pump
afterrinse
stop
emptying mixer