Maintenance and service
Check relay 1
After pressing the "Start" key for the 4th time, relay 1 is tested.
•
The red LED flashes, relay 1 is switched on and off every
second.
•
Check the function of the relay at the connection cables with a
continuity tester or a voltmeter, depending on the wiring.
Checking the relay 2
After the 5th actuation of the "Start" key, relay 2 is tested.
•
The green LED flashes, relay 2 is switched on and off every
second.
•
Check the function of the relay at the connection cables with a
continuity tester or a voltmeter, depending on the wiring.
Checking the solenoid valve
After pressing the "Start" key for the 6th time, the solenoid valve is
tested.
•
The yellow LED flashes and the valve is opened and closed
every second.
Checking the actuator board LED
After the 7th actuation of the "Start" button, the white actuator
LED is checked.
•
The blue LED flashes and the measuring LED is switched on and
off every second.
Checking the peristaltic pump
After pressing the "Start" key for the 8th time, the peristaltic pump
is tested.
•
The red LED flashes and the peristaltic pump is switched on and
off every second.
Checking the agitator
After pressing the "Start" key for the 9th time, the agitator is
tested.
•
The red and blue LEDs flash and the agitator is switched on.