140 • Using Maintenance Mode
Gas Tracer Operator’s Manual, CSA Version
3. Press the POWER ENTER button to display the warning setting for the
combustible channel. It will be flashing.
4. Use the AIR
▲
or (SHIFT)
▼
buttons to change the warning setting.
5. Press POWER ENTER to save the setting. The alarm setting for the
combustible gas channel will then be displayed.
6. Use the AIR
▲
or (SHIFT)
▼
buttons to change the alarm setting.
7. Press POWER ENTER to save the setting. The unit will direct you back to the
Alarm Points Screen where you can use the AIR
▲
or (SHIFT)
▼
buttons to
select the oxygen channel.
Press POWER ENTER.
10
%LEL
MAINTENANCE
CH
4
WARNING
50
%LEL
MAINTENANCE
CH
4
ALARM
- - -
%
MAINTENANCE
O
2
ALARM--P