WARNING:  
If the information in these instructions are not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR  SAFETY
Do not store or use petrol or other flammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualified 
installer, service agency or the gas supplier.

920-234a

Greenfire

®

 GF950L 

Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com.au

Installer: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

MODELS:   GF950LNG-2
                   GF950LLP-2
                   GF950LULPG-2

LISTINGS AND CODE APPROVALS

These  gas  appliances  have  been  tested 
in  accordance  with  AS  5263.0,  AS/NZS 
5263.1.3 and have been certified by IAPMO 
Oceana  for  installation  and  operation  as 
described in these Installation and Operating 
Instructions.

Must be installed as per AS/NZS5601

Your unit should be serviced annually by 
an authorised service person.

 

FOR YOUR  SAFETY

 What to do if you smell gas:
 

Do not try to light any appliance.

 

Do not touch any electrical switch. 
Do not use any phone in your 
building.

 

Immediately call your gas supplier 
from a neighbour's phone. Follow 
the gas supplier's instructions.

 

If you cannot reach your gas 
supplier, call the fire department.

March 1, 2021

Содержание Greenfire GF950L Series

Страница 1: ...eowner Please keep these instructions for future reference MODELS GF950LNG 2 GF950LLP 2 GF950LULPG 2 LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS 5263 0 AS NZS 5263 1 3 and have been certified by IAPMO Oceana for installation and operation as described in these Installation and Operating Instructions Must be installed as per AS NZS5601 Your unit should be...

Страница 2: ...tep by step pairing video please visit regency fire com au Customer Care Fireplace Care Videos Note The Remote Control Handset has a set of unique ID codes that is pre programmed into its memory This set of ID codes helps to differen tiate one Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset regency com ...

Страница 3: ...ns 37 Clearances 38 Flueing Introduction 39 Flue Arrangements for Horizontal Terminations Inline Horizontal Flue Chart 39 Flue Restrictor Position 39 Horizontal Terminations Inline Power Flue 102mm x 168mm Flex Flue 40 Unit Installation with Horizontal Termination 102 mm x 168 mm Flueing Flex Flue Systems 41 AstroCap Dimensions 41 Horizontal Terminations Inline Power Flue Rigid Pipe 102 mm x 168 m...

Страница 4: ... Normal Operating Sounds Of Gas Appliances 77 Resetting the Unit 77 Maintenance 78 Fan Service 78 Maintenance Instructions 79 General Flue Maintenance 79 Glass Gasket 79 Glass Door 79 Glass Replacement 79 Troubleshooting 80 Glass Door Installation 81 Valve Tray Replacement 82 End of Line Power Flue Maintenance External Power Flue Access 83 End of Line Power Flue Maintenance Internal Power Flue Acc...

Страница 5: ...PLIANCE DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS NEAR THIS APPLIANCE DO NOT OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE 908 602c Part 920 292 Colour Black on Grey Size 100 7 W x 2 7 H June 17 20 draft for approval Oct 9 20 change LP to Propane Serial Number Regency Gas Fireplace 547 Electrical 240V 50 Hz 920 292 Gas Type NG Propane ULPG Model GF950LNG 2 GF950LLP 2 GF950LU...

Страница 6: ... 332mm 1000mm 480mm 1034mm 142mm 436mm Black Premium Glass Fascia Unit with Finishing Trim Flush Finish Unit shown with Black Flat Fascia DIMENSIONS dimensions UNIT DIMENSIONS 996mm 1091mm 113mm 540mm 890mm 332mm 159mm 726mm 796mm 933mm 14mm 523mm 560mm 258mm 500mm 74mm ...

Страница 7: ...ed maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination THIS UNIT MUST ALWAYS TERMINATE FLUE DIRECTLY TO THE OUTDOORS IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The GF950L Direct Vent Fireplace must be installed in accordance with these instructions Carefully read all theinstructionsinthismanualfirst Consultthe authority having jurisdiction...

Страница 8: ...efer to Flueing section Determine which flue option will be used and if it will be terminated horizontally and or vertically Optional flues are noted below Non power Flue Natural flue Power Flue End of line Power Flue inline 2 Assemble the standoffs and nailing strips Referto UnitAssemblyPriortoInstallation 3 Slide unit into place 4 Install flue Refer to Flueing Arrangement sections 5 Make gas con...

Страница 9: ...e Opening Hot Air Outlet B Sidewall on one side 146mm Side of Fireplace Opening C Ceiling room and or alcove 1003mm Top of Fireplace Opening D Mantel Depth max 305mm 420mm Above Fireplace Opening E Alcove Width 1480mm Sidewall to Sidewall Minimum F Alcove Depth 787mm Front to Back Wall Maximum G From Floor 605mm Top of Fireplace Opening Hot Air Outlet Note 0 No hearth required Installed close to c...

Страница 10: ...equiredwhenchoosingthecombustibleflushfinishingoption Note must maintain 13mm air gap all around the perimeter of the appliance when choosing this option D G H Non Combustible Facing Header F E I J K L Flex or Rigid Pipe Drywall or other facing C C A B C Timber Studs Finished Floor A B C Timber Studs Finished Floor Non combustible Flush Finishing Framing A 1 Steel Stud on edge NOTE Donotplacetimbe...

Страница 11: ... noted with the nailing strips set as far forward on the firebox as possible The nailing strips can be adjusted back up to 38mm to allow for varying thicknesses in non combustible material wall finishes INSTALLATION ACCESS PANEL The unit is equipped with a removable access panel for pre finish installation of optional components this panel is located on the lower front face 1 Remove 4 screws to re...

Страница 12: ...ling strip is fixed during transit to the rear of the appliance Do not place any reinforcement in front of header and behind finishing material The top nailing strip must be used It is fixed during transit to the rear of the unit NOTE The appliance must be installed on a flat solid continuous surface For example a wood metal or concrete floor In a raised on the wall application the appliance must ...

Страница 13: ...facing is high quality or the paint may discolour Note Combustible mantel starts at 796mm 618mm 178mm from unit base COMBUSTIBLE MANTEL LEG CLEARANCES Mantel leg combustible finishing clearances as per diagram Combustible Material 152mm 305mm 0mm 618mm To unit base 254mm Top of Fireplace Opening 508mm 305mm 407mm 178mm Combustible Stud On Edge Nailing Flange Combustible facing min 10mm max 19mm 23...

Страница 14: ...ss panel removed 4 Reinstall access panel line up 2 upper tabs and secure in place with 4 screws Note Access panel is no longer usable accessible once facing material installed Installation Access Panel Remove 7 standoffs REMOVE TOP NAILING STRIPS STANDOFFS Remove the top nailing strip standoff by removing 4 screws in locations shown in Diagram to the right then lift off and recycle NON COMBUSTIBLE...

Страница 15: ...the mantel and the facing is high quality or the paint may discolour Note Combustible mantel starts at 796mm 605mm 191mm from unit base NON COMBUSTIBLE MANTEL LEG CLEARANCES Mantel leg Non combustible finishing clearances as per diagram Flushed Finish Allowablemantel leg projection 181mm 254mm 330mm 38mm MANTELLEG 102mm 178mm Allowablemantel leg projection 181mm 254mm 330mm 38mm MANTELLEG 102mm 17...

Страница 16: ...d sides must also be used NOTE Theappliancemustbeinstalledon aflat solid continuoussurfaceFor exampleawood metalorconcrete floor In a raised on the wall ap plication the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 796mm 605mm 1165mm Non combustible Combustible Combustible Steel Stud on edge Timber Stud Timber Stud 159mm 446mm Non Combust...

Страница 17: ...e chart for install height and heat deflector depth Note The TV mounting bracket can not be secured directly to the appliance It must be secured to framing The TV depicted in the picture may need to be higher depending on the style of TV mounting bracket used The mounting bracket shown is a simple single strip TV secured to framing L 51mm A B C 13mm Air Gap A Depth of TV Mounting Bracket B Height ...

Страница 18: ... installation M 5 3 4 146mm 14 9 16 370mm DETAIL M SCALE 1 6 INSTALLING A TV ARTWORK ENCLOSED ABOVE THE UNIT Maximum recess depth is 146mm Minimum height is 370mm from top lip Ensure framing does not interfere with flueing 370mm 146mm ...

Страница 19: ...t bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of the steel stud is facing the timber framing 468 025 Flat side out 5 Secure horizontal steel header stud 468 039 with 2 screws per side as per diagram 6 Slide the unit into position Hook up gas flueing electrical and conversion kit if purchased prior to installing the remaining steel studs 7 Secure the upper horizontal steel stu...

Страница 20: ...ed with non combustible required materials to specific dimensions above and aroundtheunits Thisisduetotheseareasreachinghighertemperature levels than required acceptable for a combustible material To obtain the best most durable finish around your fireplace this calls for a high level of care and attention to the preparation and finish around this appliance using only the highest quality materials...

Страница 21: ...cessive condensation on glass doors poor flame package carbon blue flames etc These are not product related issues 3 The unit does not have to be completely enclosed in a chase You must maintain clearances from the flue to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the appliance base 4 Non combustible material ie tile slat...

Страница 22: ...refer to the following instructions 1 Remove the glass door and inner panels see instructions in this manual 2 Remove6screws 3front 3back toremoveheatbaffletoaccessrestrictor plate 3 Remove the screws that hold the flue restrictor in place FLUE RESTRICTOR POSITION Heat Baffle 4 Adjust the flue restrictor plate to the required flue restrictor position as per the diagrams shown below 5 Once the flue...

Страница 23: ... GF950L 2 Gas Fireplace 23 installation EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS NZ 5601 ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCE NATURAL FLUE ...

Страница 24: ...250MJ h input 1500 All fan assisted flue appliances in the direction of discharge k From a mechanical air inlet including a spa blower 1500 n Vertically below an openable window non mechanical air inlet or any other opening into a building iwth the exception of sub floor ventilation Space heaters up to 50MJ h input 150 Other appliances up to 50 MJ h input 500 Appliance over 50 MJ h input and up to...

Страница 25: ...6DVA 48B 1524 mm Pipe Length Galvanized 46DVA 60 1524 mm Pipe Length Black 46DVA 60B Extension Pipe 216 mm Galvanized 46DVA 08A Extension Pipe 216 mm Black 46DVA 08AB Extension Pipe 406 mm Galvanized 46DVA 16A Extension Pipe 406 mm Black 46DVA 16AB 45º Elbow Galvanized 46DVA E45 45º Elbow Black 46DVA E45B 90º Elbow Galvanized 46DVA E90 90º Elbow Black 46DVA E90B 102 MM X 168 MM RIGID PIPE CROSS RE...

Страница 26: ...2 Vinyl Siding Standoff 46DVA VSS FPI 946 506 P Vent Guard Optional for AstroCap 946 523 P AstroCap Horizontal Cap 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 206 Vinyl Siding Standoff for AstroCap Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 102 mmx 168 mm Venting For specific instructions on venting components visit the manufacturers websi...

Страница 27: ...NG ARRANGEMENT FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Simpson Dura Vent Only Maintain clearances to combustibles as listed in Clearances section Horizontal flue must be supported every 0 9m A flue guard sh...

Страница 28: ...ble outer liner Kit length 2 102mm flexible inner liner Kit length 3 spring spacers 4 thimble 5 AstroCap termination cap 6 screws 7 tube of Mill Pac 8 plated screws 9 S S screws 8 x 1 1 2 drill point 946 516 3 m FLUEING ARRANGEMENTS NON POWER FLUE HORIZONTAL TERMINATION FLEX Regency Direct Vent System These flueing systems in combination with GF950L have been tested and listed as a Direct Vent sys...

Страница 29: ...g and add 51mm When using Rigid Flue other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor WARNING Do not combine flueing components from different flueing systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems ThisproducthasbeenevaluatedbyIntertek forusingaRigidPipeAdaptorinconjunction with Duravent Direct Vent The FPI AstroCapTM and Re...

Страница 30: ...o or two 45o elbows is permitted 2 Minimum distance between elbows is 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal flue must be supported every 0 9m Must use optional rigid pipe adaptor Part 510 994 when using Duravent systems A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes Flex system can on...

Страница 31: ...ustibles as listed in the Clearances section in the manual Horizontal flue must be supported every 1M Refer to the Flue Restrictor Position section for details on how to change the flue restrictor from the factory setting of Set 0 or Set 3 if required Note For ULPG Flue Restrictor Set to 0 75mm open FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS NON POWER FLUE Vertical Flueing with Two 2 45o Elbows...

Страница 32: ...ng non combustible brac ing to stop movement On penetration of roof fit an appropriate flashing or weather seal to suit the roofing material ensure all joints outside are sealed with appropriate sealer 6 Fit gas cowl 46DVA VCH 9 or flomet cap 946 651 ensuring inner and outer flue pipes are sealed Gas cowl part number 46DVA VCH 9 or Flomet cap part number 946 651 GF950L only 7 Start heater and run ...

Страница 33: ...e chimney system 15 Slide storm collar over pipe length until it reaches the flashing 16 Install termination cap by twist locking it 17 Secure the flashing to the roof using screws Note Any closets or storage spaces which the vent passes through must be enclosed Roof Pitch Minimum Vent Height Meters 0 61 0 61 0 61 0 76 0 99 1 22 1 52 1 83 2 13 2 29 flat to 30 26o over 30 26o to 33 69o over 33 69o ...

Страница 34: ...ng may also be used if further supports are required VERTICAL FLUE EXTENSION KIT PART 946 756 6 1 m Flex pipe Extension Used in conjunction with the 946 768 Vertical Flex kit and 948 367 P flex to flex adaptor 3 wall straps flex adaptor 102 mm inner pipe 6 m 168 mm outer flex pipe 6 m 10 spring spacers 1 919 698 06 12 18 60 1 4 Ceiling firestop Diagram 1 Diagram 1a Enclosure Ceiling firestop Flashi...

Страница 35: ...ions through the flashing until the height of the flue cap meets the minimum height requirements specified in local codes Note that for steep roof pitches the vertical height must be increased A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the flue height may solve the problem Pipe Length Flashing Rigid Pipe Adapt...

Страница 36: ...om sharp edges DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS GND RESET SWITCH NC JUMPER 2 1 910 514 910 936 BROWN BLUE GREEN GREEN GND WHITE WHITE BLACK BLACK BLACK FLAME SENSOR ECS 5 NON POWER VENT APPLICATION 911 183 911 243 FAN 2 1 3 910 912 BLACK RED BROWN BROWN GREEN BLUE PRESS SWITCH NO room fan 910 780 910 896 911 310 4 911 318 911 316 911 317 RED ON OFF 911 113 ...

Страница 37: ...F950L 2 Gas Fireplace 37 installation EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS NZ 5601 ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCE INLINE POWER FLUE ...

Страница 38: ...h input 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air inlet or any other opening into a building iwth the exception of sub floor ventilation Space heaters up to 50MJ h input 150 Other appliances up to 50 MJ h input 500 Appliance over 50 MJ h input and up to ...

Страница 39: ... Minimum 4 ft 1 2 m from the unit Important Maximum total vent length 60 18m maximum of six 90 elbows permitted One 90 elbow two 45 elbows Maximum total negative vent length 7 2m Note Maximum length of 60 feet 18m is based on overall length of combined chimney components Do not run positive venting after a negative run Restrictor Set 3 18mm open Maximum allowable negative run 7 ft 2 1 m Inline blo...

Страница 40: ...runs are required rigid pipe must be used 5 Must use adaptor pipe 946 219 P to connect inner flex pipe as shown IMPORTANT The inline power flue must be installed within the confines of the home structure and must be accessible for future servicing An access hole as noted in this manual or an attic space would be suitable Maximum total flue length 18m maximum of six 900 elbows permitted One 900 elb...

Страница 41: ...which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90o The liners must slip over the collars a minim...

Страница 42: ... 510 994 920 210 04 01 20 6 CV72EPV CB72EPV Inline Power Vent Vertical or Hortizontal Installation Instructions Horizontal Terminations Inline Power Vent Rigid Pipe 4 x 6 5 8 The minimum components required for a basic horizontal termination are 1 Horizontal Termination Cap 1 Power Vent Kit 1 Rigid Pipe Adaptor 1 Vent Reducer 1 Length of pipe to suit wall thickness and total vent run see Table 1 A...

Страница 43: ... to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips Note For best results and optimum performance with each approved flueing system it is highly recommended to apply Mill Pac sealant to every inner pipe connection Failure to do so may result i...

Страница 44: ...Horizontal Power flue 6 m 1 X 946 755 Vertical Flex kit for inline power flue 6 m includes Cowl The gas power flue system is designed to allow the installation of a gas appliance when typical natural vent configurations shown in this manual are not possible Restrictor set on 3 18mm Inline power flue location restrictions from inline PV rmination cap from top of unit o inline PV Min 0 6m from inlin...

Страница 45: ... 12 Put a bead of Mil Pac around the inner pipe adaptor supplied with the inline power flue and attach the inner pipe adaptor to the inner collar of the inline power flue see Diagram 3 next page 13 Put a bead of Mil Pac around the other end of the inner pipe adaptor and slide the 101mm flex over the collar of the inner pipe adaptor secure with 3 screws 14 Install 101mm spacers around 101mm flex 15...

Страница 46: ...ipe Ceiling Firestop Roof Support Brace Flashing Storm Collar Termination Cap Ceiling Firestop Inline Power Flue Terminal Inner Pipe Adaptor shown inside flex pipe Enclosure Flex Pipe Ceiling Firestop Roof Support Flashing Elbow Support Termination Cap Storm Collar Ceiling Firestop Support to prevent sagging Inline Power Flue Terminal Enclosure Ceiling firestop Flashing Termination Cap Storm Colla...

Страница 47: ... 3 in total for this purpose All round plumbers strapping may also be used if further supports are required VERTICAL FLUE EXTENSION KIT APPROVED MODELS HORIZONTAL POWER VENT KIT CV72EPV CB72EPV CB40EPV CV40EPV CC40EPV ONLY PART 946 756 6m Flex Pipe Extension 3 wall straps flex adaptor 102mm inner pipe 168mm outer flex pipe 6m 10 spring spacers Note The flex adaptor which is included with this kit ...

Страница 48: ...2 0 61 over 7 12 to 8 12 2 0 61 over 8 12 to 9 12 2 0 61 over 9 12 to 10 12 2 5 0 76 over 10 12 to 11 12 3 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 12 7 2 13 over 18 12 to 20 12 7 5 2 29 over 20 12 to 21 12 8 2 44 The FPI AstroCapTM and FPI RiserVent terminal are certified for installations using FPI venting systems as well as Simpso...

Страница 49: ...of the flue cap meets the minimum height requirements specified in Diagram 5 or local codes Note that for steep roof pitches the vertical height must be increased firestop spacer framing 10 254mm square hole 11 11 Diagram 3 Note Forbestresultsandoptimumperformance with each approved flueing system Mill Pac sealant is strongly recommended at everyinnerpipeconnection Failuretouse Mill Pac may result...

Страница 50: ...o the bypass plate may not be accessible for further adjustment A bypass plate is used to adjust the flowrate of the exhaust being pulled from the unit To adjust the bypass plate Bypass Adjustment 1 Remove the four screws on the bottom access panel 2 Remove the two screws on the bypass plate and slide the plate to the appropriate setting refer to unit s flue chart 3 Reinstall the bypass plate scre...

Страница 51: ...Regency GF950L 2 Gas Fireplace 51 433mm 111mm 396mm 297mm 614mm 362mm 408mm 362mm 279mm 254mm 148mm 113mm 163mm 82mm 312mm 362mm 114mm INLINE POWER FLUE DIMENSIONS installation ...

Страница 52: ...agram 1 Inline power flue oriented vertically Diagram 2 Inline power flue oriented horizontally Pressure switch orientation if inline power flue is oriented vertically see Diagram 1 Pressure switch orientation if inline power flue is oriented horizontally see Diagram 2 IMPORTANT The pressure switch must be oriented as shown below Gas Power Flue Installation Framing Inline Power Flue Terminations T...

Страница 53: ... switch in a horizontal position follow the steps below 1 Remove the 2 screws connecting the pressure switch mount to the mounting bracket 2 Turn the mounting bracket 90 degrees line up the holes and screw the bracket back onto the mount Pressure switch side P Pressure switch side V Pressure switch installed IMPORTANT Pressure switch must always be oriented vertically inside the inline power vent ...

Страница 54: ...configuration Diagram 1 51mm clearance is required on sides in a vertical configuration Diagram 2 305mm clearance is required on ends in a vertical configuration Diagram 1 A framed access hole with dimensions of 305mm x 406mm is required to access the access panel if the inline power flue is placed behind a wall Diagram 3 The access hole can be covered with an open air louver cover which allows 50...

Страница 55: ... system that will be used Once the flue system has been installed the wire harness may then be brought to the appliance as per steps below 2 Run the power flue wire harness from the inline end of line power flue to the appliance Excess wire can be rolled up as shown below and placed where space is available such as in an attic space or within a chase 5 Run the wires into the appliance until the st...

Страница 56: ...onvection Fan control ON Convection Fan is always on if the burner is lit OFF Convection Fan is capable to be switched off independent of the burner 2 Model Selection ON Power Flue mode OFF Non Power Flue mode 3 Gas Type Selection ON Natural Gas OFF Propane ULPG 4 Spare N A IMPORTANT The convection fan must always remain in the ON position Do not turn this to the OFF position 1 2 3 are all shown i...

Страница 57: ...1 243 ORANGE ORANGE WHITE 911 112 2 1 3 4 RED RED WHITE BLACK CAPACITOR WHITE ON OFF 911 113 BLACK OPTIONAL WIFI MODULE 911 322 920 342 ECS V GF950L PV WIRING DIAGRAM WIRING DIAGRAM POWER FLUE DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS DO NOT CUT THE GROUND TERMINAL OFF UNDER ANY CIRCUMSTANCE CAUTION ENSURE THAT THE WIRES DO NOT TOUCH ANY HOT SURFACES AND ARE AWAY FR...

Страница 58: ...F950L 2 Gas Fireplace installation EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS NZ 5601 ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCE END OF LINE POWER FLUE ...

Страница 59: ...h input 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air inlet or any other opening into a building iwth the exception of sub floor ventilation Space heaters up to 50MJ h input 150 Other appliances up to 50 MJ h input 500 Appliance over 50 MJ h input and up to ...

Страница 60: ...hibited The gas power flue system is designed to allow the installation of a gas appliance when typical natural flue configurations are not possible Must be terminated horizontally Vertical terminations are not permitted Important Maximum total flue length 18m maximum of six 90 elbows permitted One 90 elbow two 45 elbows Maximum total negative flue length 2m Minimum 1 22 m from the unit prior to t...

Страница 61: ...er Fasten the cap to the outer wall with the 4 supplied screws 5 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fire place You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90 The liners must slip over the collars a minimum of 35mm 6 Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner...

Страница 62: ...allthickness Flat Wall Installation Wall Thickness mm Flue Length Required mm 102mm 140mm 152mm 178mm 216mm 229mm 254mm 292mm 305mm 229mm 368mm 279mm 371mm Adj Pipe 381mm 597mm 432mm 610mm Adj Pipe Adj Pipe Length Rigid Pipe Adapter Part 510 994 o 90 Elbow Pipe Length Power Flue Trim Power Flue Terminal Frame Assembly Power Flue Frame Power Flue Kit Part 946 542 Table 1 Power Flue Kit with Flue Te...

Страница 63: ... Note For best results and optimum performance with each approved flueing system it is a minimum to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Horizontal runs of flue must be supported every 0 9 meter Wall straps are available for this purpose 6 Mark the wall for a square hole see chart to ...

Страница 64: ...Wipe any excess silicone off outer flange after flange is screwed down Silicone edge of inner trim against siding of structure wipe any excess silicone off trim Fan discharge opening 343mm 343mm 3 Determine the building finishing material thickness 4 Dependingonthebuildingmaterialthickness installtheframeontothe Power Flue mount using 4 screws Mounting holes start at 51mm from the front of the Pow...

Страница 65: ... local authorities When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff valve should be supplied in or near the unit or as per local codes for ease of servicing this appliance GF950L NG SYSTEM DAT...

Страница 66: ...ning resulting from improperly setting the aeration controls is NOT covered under warranty Minimum Air Shutter Opening for Power Flue NG 4 4 mm Propane 11 mm ULPG 13 mm Note Ensure aeration is set to correct configuration 845 S I T VALVE DESCRIPTION 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 ConnectionforPressureRegulator Comb...

Страница 67: ...fire hazard 6 Plan the location of the fireplace and the warm air duct runs see diagram 1 as a guide for possible duct runs and locations Diagram 1 Guide for possible air duct runs and locations Keep duct length and number of bends to a minimum Maximum duct length is 9 0m The Extension Kit contains a maximum of up to 4 5m Please purchase the Fan Duct Extension Kit to increase the 9 0m MINIMUM FRAM...

Страница 68: ...an Housing See diagram 4 8 Remove the knock out on the top of the unit Cut out the insulation Remove the second and thirdknockout botharebelowthetopknockout 9 On the top of the unit bend the 3 tabs up Insert the Duct collar Secure the collar to the 3 tabs with screws 10 Attach fan duct to the unit Slide the ducting over the collar and secure with screws 11 Final step double check the fan ducting c...

Страница 69: ...nsure that the wires do not touch any hot surfaces and are away from sharp edges AlternateSwitches Mayusethefollowing Checkwithlocalauthoritiesandelectrician CLIPSAL 203 2E45 OUD Dimmer CLIPSAL 2031 VF3CSF 3 Speed CAUTION Labelallwirespriortodis connection when servicing controls Wiringerrorscancauseimproperand dangerous operation Wire Nut Wire Nut Wire Nut Rheostat Wire Nuts Wire Wire Brown Hot B...

Страница 70: ...nder warranty Log kit 466 930 contains the following pieces 1 Line up locators on Log 1 with corresponding locators on Log Tray as shown in Diagram 2 2 Line up locators on Log 2 with corresponding locators on Ceramic Log Burner as shown in Diagram 3 3 Line up locator on Log 3 with corresponding locator on Ceramic Log Burner as shown in Diagrams 4 and 5 Diagram 2 Diagram 3 Diagram 4 Diagram 5 3 4 5...

Страница 71: ...d Log 3 as shown in Diagram 9 8 Line up locator on bottom of Log 7 with locator on Ceramic Log Burner as shown in Diagram 10 6 Log 5 final position shown in Diagram 8 6 Log 8 in final position shown in Diagram 11 Place supplied embers over burner screw holes in locations shown below Diagram 7 Diagram 8 Diagram 9 Diagram 10 Diagram 11 Log 8 and ember locations Diagram 6 3 6 1 3 8 7 4 4 1 1 2 2 2 4 ...

Страница 72: ...ece 3 Reverse steps to reinstall 1 Remove burner side panels by lifting them up and out 2 Remove front trim piece see instructions above 3 Remove two 2 screws in locations shown below to release panel clips 4 Remove panels by sliding out 5 Reverse steps to reinstall Front Trim Piece Panel Clip Screw Locations Panel Clip Diagram 1 Front Trim Screw Locations INNER PANEL REMOVAL INSTALLATION FRONT TR...

Страница 73: ... first mounting slot the one clos est to the door frame overlay out of the 3 so that the faceplate and door frame overlay are flush with one another See diagram 2 1 Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side ofthe firebox as shown below Diagram 3 Diagram 4 Deflector Installed NOTE When installing the stainless steel fasci...

Страница 74: ...een Mesh over Inner Door Frame as shown in Diagram 1 3 Install Screen and Inner Door Frame to unit over glass door frame as shown in Diagram 3 Lower gently once in position over glass door frame 2 Bend Tab on Screen Mesh to 90º as shown in Diagram 2 Secure to Inner Door Frame with one 1 screw as shown in Diagram 2a Diagram 1 Diagram 3 Diagram 2 Diagram 2a ...

Страница 75: ...s is to accommodate any finishing that protrudes slightly beyond the faceplate Warning Turn off the unit by way of the wall switch or remote Allow unit to cool at least 10 min prior to removing the faceplate Diagram 1 Glass Surround Install Diagram 3 Final Install Diagram 2 adjustments 1 4 6mm 1 2 13mm Use first notch in bracket for standard installation 919 615a 05 27 16 1 OPTIONAL FINISHING TRIM...

Страница 76: ...ning NOTE The main burner will always start on HIGH and resume it s last setting after 20 seconds of operation NOTE Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE APPLIANCE WITH OUT THE GLASS FRONT IN PLA...

Страница 77: ...erate with blue flames with slight yellow tips may exhibit slight carbon deposition FOR YOUR SAFETY READ BEFORE LIGHTING SUITABLE ONLY FOR INDOOR INSTALLATION A BEFORE LIGHTING smell all around the appliance areaforgas Besuretosmellnexttothefloorbecause some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric ...

Страница 78: ...wn in Diagram 1 4 Remove burner by removing 2 screws in locations shown below 7 Loosen three 3 screws to remove heat deflector shown in Diagram 5 8 Remove two 2 screws to remove fan shown in Diagram 6 9 Reverse steps to reinstall fan 6 Remove access panel by removing eight 8 screws in locations shown in Diagram 4 Diagram 3 Log Tray screws Diagram 5 Heat Deflector Screws Diagram 6 Fan Screws Diagra...

Страница 79: ...inspection of the flueing system semi annually Recommended areas to inspect as follows 1 Check the Flueing System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the termination cap and shine a flashlight down the Flue Remove any bird nests or other foreign materia...

Страница 80: ...on lead or power board Check polarity at power point connection into heater and ECS control box Faulty Ignition Module Replace Ignition module Pilot light ignites but main burner does not ignite igniter stop sparking and pilot flame stays on No Gas to main burner Check burner injector for blockage Pressure switch not activating Ensure Fan is running Clear any blockage in hose from pressure switch ...

Страница 81: ...ed or broken Replacement of the glass panels should be done by a licensed or qualified service person Glass should be cool if cleaning is necessary Door Tool Upper Door Hooks Lower Door Latches Handling of Ceramic fiber log sets and brick panels When installing or removing ceramic fiber log sets or ceramic brick panels if installed from an appliance we recommend that you use latex gloves and a P1 ...

Страница 82: ...e tray and reverse steps Diagram 4 Valve Tray Screw Locations Diagram 5 Valve Tray Removal 1 Remove faceplate inner frame glass door front trim piece and inner panels see instructions in this manual 2 Remove logs 3 Remove burner side panels by lifting out as shown in Diagram 1 4 Remove burner by removing 2 screws in locations shown below Diagram 3 Log Tray screws Diagram 1 Burner Side Panels Diagr...

Страница 83: ...rbydisconnectingblackandblackwireandwhite and black wire Diagram 8 The power flue motor is now free from the unit 5 Loosen 4 screws and slide shield up and out Diagram 2 Once access to the power flue housing is achieved you can remove the pressure switch and fan motor 6 Remove the pressure switch by disconnecting the red and green wires from the pressure switch Diagram 3 7 Disconnect the hose from...

Страница 84: ...er flue harness END OF LINE POWER FLUE MAINTENANCE INTERNAL POWER FLUE ACCESS Note May only be accessed if an access panel was installed for servicing from inside 1 Turn off the power 2 Remove 8 Phillips head screws from the rear of the power flue see Diagram 1 3 Slide the power flue housing out through the back as shown in Diagram 2 4 Turn the power flue over to the front side Diagram 3 5 Follow ...

Страница 85: ... it by removing 1 one Phillips head screw holding the pressure switch to the mounting bracket Diagram 4 Replacing the power flue motor 1 Turn off power supply 2 Loosen 6 x 6 35mm hex screws slightly 3 Turn power flue motor counter clockwise and lift out Diagram 5 4 Disconnect the power to the motor by disconnecting the white and white from the terminal block The power flue motor is now free Diagra...

Страница 86: ...e checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these o...

Страница 87: ...tletValveTo Burner Orifice N S 904 599 Fitting Elbow 90 Degree N S 904 600 Fitting Elbow 90 Degree N S 904 650 Fitting 1 8 Brass Pipe Adaptor N S 904 771 Fitting 3 8 Tube to 1 2 Pipe N S 904 911 Fitting Connector 1 2 MIP x 1 2 Flare N S 936 170 Burner Orifice Gasket N S 911 113 Switch On Off W CAT 5 Cable 3 FT 105C N S 910 912 Wire Harness From Module To Valve N S 910 896 High Temperature Wire To ...

Страница 88: ...88 Regency GF950L 2 Gas Fireplace PARTS LIST parts list 15 26 10 9 12 17 4 5 18 23 2 1 19 24 16 27 7 13 25 25 22 13 11 20 12 8 6 3 MAIN ASSEMBLY ...

Страница 89: ... door frame Gloss Black w Screen 33 467 544 Door Frame Overlay Black 34 468 934 Fascia and Door Frame Black w Screen 468 936 Fascia and Door Frame Stainless Steel w Screen 468 951 Fascia Black Glass not shown N S 468 900 Steel Stud Framing Kit N S 468 928 Finishing Trim N S 946 767 Wifi Dongle ECS V N S 946 765 Horizontal Vertical Inline Power Flue N S 946 542 Horizontal End of Line Power Flue ...

Страница 90: ...ol Box N A N A N A N A N A N A N A 911 307 Control Box N A N A N A N A N A N A N A N A N A 910 527 Manual Control Switch N A N A N A N A N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 911 316 Control Box Cable 5 911 317 Control Box Cable 6 911 318 Control Box Cable 7 911 319 Control Box Cable 8 N A 2 1 1...

Страница 91: ...Faceplate 6 946 130 Power Flue SS Outer Perimeter Trim 7 946 157 Power Flue SS Water Deflector 8 911 047 Silicone Tubing Sold Per Foot 6 inches required For Power Flue 9 946 163 Pressure Switch Sensor Bracket 10 946 539 Power Flue Outer Intake Assembly N S 946 540 Power Flue Inner Intake Assembly N S 911 339 PV Wiring Harness N S 911 340 Capacitor N S 910 006 Terminal Block N S 468 061 Terminal Bl...

Страница 92: ...son Duravent Collar 11 666 180 Outer Flue Gasket 12 N A Ceramic Paper 13 N A Outer Cover 14 666 170F Bypass Plate 15 N A Ceramic Plate 19 666 172 Pressure Switch Bracket Holder 20 666 173 Pressure Switch Bracket Mount 21 666 174 Mounting Leg with Heat Shield 22 911 047 Silicone Hose sold per foot 1 foot required 23 911 047 Silicone Hose sold per foot 1 foot required N S 911 339 PV Wiring Harness N...

Страница 93: ...Regency GF950L 2 Gas Fireplace 93 NOTES notes ...

Страница 94: ...components Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts abo...

Страница 95: ...general practice of FPA to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPA and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the inst...

Страница 96: ...r movement expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any dam...

Страница 97: ...to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than servic...

Страница 98: ...ervices Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 Phone 08 9350 2200 Fax 08 9353 4225 New Zealand Aber Hol...

Страница 99: ...k to us and we will register the warranty for you It is important you provide us with all the information below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer P...

Страница 100: ......

Страница 101: ...Regency GF950L 2 Gas Fireplace 101 NOTES notes ...

Страница 102: ...102 Regency GF950L 2 Gas Fireplace NOTES notes ...

Страница 103: ......

Страница 104: ...Fireplace Products International Ltd Copyright 2021 FPI Fireplace Products International Ltd All rights reserved IMPORTANT A certificate of compliance or equivalent by an authorised installer must be obtained on commissioning of appliance to obtain warranty ...