Configuration for All Measurement Types
R&S
®
NRX
52
User Manual 1178.5566.02 ─ 07
Remote command:
Scaling
Configures the display scaling. The available parameters depend on the following set-
tings:
●
●
Scale Lower Limit ← Scaling
If
is set to "Scalar Analog", available for continuous average, burst
average, time gate, timeslot measurements.
Defines the lower limit of the bargraph display.
Remote command:
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:
RATio:RCOefficient
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:
RATio:RFRatio
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:
RATio:RLOSs
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:
RATio:SWR
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:
RATio[:VALue]
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA][:
POWer]
Scale Upper Limit ← Scaling
If
is set to "Scalar Analog", available for continuous average, burst
average, time gate, timeslot measurements.
Defines the upper limit of the bargraph display.
Remote command:
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:
RATio:RCOefficient
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:
RATio:RFRatio
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:
RATio:RLOSs
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:
RATio:SWR
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:
RATio[:VALue]
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA][:
POWer]
Forward Scale Lower Limit, Reflection Scale Lower Limit ← Scaling
Available for NRT measurements.
Display Settings
www.allice.de
Allice Messtechnik GmbH