Remote Control Commands
R&S
®
NRX
259
User Manual 1178.5566.02 ─ 07
DISPlay[:WINDow<Window>]:TRACe:MEASurement:POWer:PULSe:TOP[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the pulse top power. See
CALCulate<Measurement>:TRACe:MEASurement:POWer:PULSe:TOP?
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<Window>]:TRACe:MEASurement:PULSe:DCYCle[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the duty cycle of the measured power. See
CALCulate<Measurement>:TRACe:MEASurement:PULSe:DCYCle?
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<Window>]:TRACe:MEASurement:PULSe:DURation[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the pulse width. See
TRACe:MEASurement:PULSe:DURation?
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See