92
User Manual Version 3.1
The three options “print acknowledge”, “data acknowledge“ and
”trig. ext. device“ are not factory-provided features and are only
available by feature update!
You can check the available features in the
SERVICE >
CONFIGURAT.
INFO
menu. Please contact your authorised
Quadient
dealer for
further information.
Pos: 81.80 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1803_RELAY1 OUTPUT_AS-ORBIT_ONLY @ 2\mod_1270651120449_912.doc @ 14431 @
Relay 1 OUTPUT
This feature is used to assign different output functions to the “Relay 1” interface. Different
supported devices can be controlled by the printer.
Option
Note
feeder control
Default option to control a feeder. The relay will
switch on the feeder when the printer is ready to
print.
single pulse
DISTANCE
PULSE
WIDTH[ms]
Universal control function for an external device.
The distance between the first print cartridge and the
device has to be entered (range 0 – 5,000 mm). The
width (duration) of the pulse can be set in a range of
0 – 200 msec. Any device in-between the printer and
the external device can influence the distance and the
pulse width.
single pulse
works for devices which are
downstream from the printer.
Trigger single pulse
The
single pulse
function must
be triggered from a PC
application.
sort(toggle)
DISTANCE
Function to control a sorting unit (e. g. a batch
kicker). The signal remains until a second signal
arrives.
The distance between the first print cartridge and the
device has to be entered (range 0 – 5,000 mm). Any
device in-between the printer and the sorting unit can
influence the distance.
sort(toggle)
works for devices which are
downstream from the printer.
Trigger sort (toggle)
The
sort(toggle)
function must
be triggered from a PC
application.
dryer
Function to turn on and off IR or UV dryers which are
Содержание AS-Orbit
Страница 1: ...User guide AS Orbit Address Printer ...