8.2.4
Emergency system cannot be released
Condition Problem Solution
The display shows the
message
EMERGENCY BUTTON
SHOULD BE RELEASED!
CODE
: 49
and the printer cannot be set
back to normal, by pressing
the green emergency release
button.
One section of the
emergency system is still
open.
Check if the red emergency
button is released.
Check if all emergency stop
connections on the machine
are set up and connected
correctly (see chapter
Emergency stop connection).
Check the emergency
buttons and connections on
all connected devices.
Pos: 97 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Troubleshooting (all printers)/8.2a_Ü3_The printer doesn't detect a connected Feeder_Systems only @ 3\mod_1279806749958_912.doc @ 24172 @ 3
8.2.5
The printer doesn't detect a connected Feeder
Condition Problem Solution
The printer does not
establish a connection and
does not control the
connected Feeder
(start/stop/speed).
A connection between the
printer and the Feeder
couldn’t be established.
Make sure to first switch on
the Feeder and second to
switch on the printer.
Check the correct connection
between the printer and the
feeder.
Check whether the
emergency stop was
activated or the emergency
stop connection is broken.
Make use of the strapping
plugs to cut the Feeder from
the emergency stop
connection of the printer
(see 3.4.9 on page 31).
Try to use the Feeder in
offline mode (control
start/stop/speed manually).