Pict. 39 -
Cleaning
the extruder - you can see the hobbed pulley through the service hole
12.5 Nozzle cleaning
Do not touch the nozzle during these procedures as it is preheated and you may
burn yourself!
To make cleaning easier, move the extruder head up. On the
LCD menu
-
Settings - Move axis - Move Z axis.
As you will be operating with the hotend.
Use a wire brush to clean the
nozzle
from the outside. Heat the
nozzle
before you do so.
Filament is pouring out a little
If the filament doesn’t go through the extruder smoothly and only a small volume is coming
out, first check if the extruder fan is working
properly
and that the temperature is set correctly
(PLA 210 °C; ABS 255 °C, HIPS 220 °C, PET 240 °C)
. Also check that the
filament
was
correctly loaded into the extruder.
If that is not the case. Follow the instructions below:
1. Heat the
nozzle
according to the
filament
you want to
from.
Load
the
filament
and push a
bundled acupuncture needle
(0,3-0,35 mm) into the
nozzle
from below
- between 1 and 2 cm deep.
2. Choose
Load filament
option from the LCD menu and check if filament is extruded
properly.
62