4-4
VIBXPER
T II 05.2012
Time waveform
The measurement results are displayed as an XY diagram in the top
section of the window (see the standard setting). The data field in the
lower half lists the two highest amplitudes (positive & negative). If a
threshold value is exceeded, the absolute value and the difference to
the measurement value is displayed ('delta', see below).
The following functions are available for evaluation of the result:
Zoom the time (X) axis
• Press the '+' key to magnify the X axis. Depending on the zoom
mode (page 4-18), the main cursor is used as the central point or
the gap between the main and delta cursor is magnified. The '–' key
is used to zoom out.
Scaling the amplitude (Y axis)
• Press the navigation key up to magnify the scaling of the Y axis and
to make low amplitudes visible.
• To reduce the scaling again, press the navigation key down.
Rotational speed marker
The yellow rotational speed markers indicate the trigger pulses dur-
ing signal measurement. In the circular plot, the speed markers also
indicate the direction of rotation (see the next page).
Cursor
The cursor coordinates are displayed above the diagram.
• Press the MENU key and click on 'Cursor'.
n
one
: Hide all cursors (Zoom / scaling not possible!)
m
ain
: Show main cursor
Press the navigation keys right/left to move the cursor. The speed
increases if you keep the navigation key pressed.
Results
Result screen of a
time waveform measurement
Zoomed area
Cursor coordinates
Threshold
Speed marker
Содержание VIBXPERT II
Страница 175: ......