5-7
VIBXPER
T II 05.2012
Measurement tasks
Left:
Runup / Coastdown
Phase - RPM (Bode plot)
Right:
Results screen during
a coastdown measurement
Phase - RPM
A.1 Selecting the measurement task via the measurement task icon:
• Highlight the respective icon in the 'Advanced' tab.
• Press the F key to display the stored measurement tasks
• Select the required measurement task using the identifier.
- d
ual
or
2-c
: 2-channel measurements
- s
pec
or
spectrum
:
'Spectrum RPM' measurement type
- o
verall
v
alue
: 'Overall Value - RPM' measurement type
-
s
tartup
:
Runup
- c
oastdown
:
Coastdown
A.2 Selecting the measurement task in the Task Manager:
• Highlight the respective icon in the 'Advanced' tab.
• Press the MENU key and click on 'Task Manager'.
• Click in the uppermost menu to display the stored measurement
tasks. The 'Show Dual Tasks' or 'Show Single Tasks' menu entries
display the available 2-channel or 1-channel tasks (see below)
• Select the required measurement task.
B. Starting the measurement
• Click on the measurement task icon.
A connected laser-trigger sensor is automatically switched on for
adjustment.
Do not look into the laser beam! Risk of eye damage!
A dialog window appears in the measurement screen in which you
can temporarily change the following setup parameters:
-
s
tart
rpm
, s
top
rpm
- rpm
deviation
-
m
easurement
range
.
• Click on 'Start' after the parameters have been set correctly.
During data collection, the relevant measurement data are dis-
played in a dialog window (see below).
WARNING!