2-5
VIBXPER
T II 05.2012
Interfaces
The connections for the sensor and data cables are located on the
front of the measurement device. The cable connectors and sockets
are colored for easy identification.
To unplug the connector, push the connector sleeve backwards to re-
lease the lock. Only then should you remove the connector from the
device. Never pull directly on the cable!
Analog
The blue channels marked with 'A' and 'B' are used as the:
- Input for analog signals
- Charging socket for the battery (A or B)
The sensor cable is connected to the channel (A or B) set in the mea-
surement task.
The analog measurement channels are not electrically insulated.
For 2-channel measurement on two machines, check the potential
equalization (VDE 0100) or use electrically insulated sensors.
Top view
Attention!
Getting started - Interfaces
Colored circle with
dot marking
Socket with notch
Connector with
dot marking
B
A
Analog
(A & B)
Temperature
(type K)
Digital Communication
Sockets and cable connectors are colored
B
A
First unlock,
then unplug!