VTrak M610p Product Manual
202
•
Linux operating systems with the 2.6 kernel support 64-bit LBA. For these
OSes, always choose the default 512 B sector size.
2 TB Limitation
If your Host PC runs Windows 2000 or Windows XP (32-bit), and you want to
create logical drives larger than 2TB, you must choose a sector size larger than
512 B when you create the logical drive. The table below correlates sector size
with logical drive capacity.
Because logical drives can be expanded, you may encounter a situation where
the usable capacity of your expanded logical drive is reduced by the addressing
issue described above. There are two alternatives:
•
Limit your logical drive expansion to within the limits described in the chart.
•
Back up your data, then delete your existing logical drive and create a new
one with a larger sector size.
Cache Policy
As it is used with VTrak, the term cache refers to any of several kinds of high-
speed, volatile memory that hold data moving from your computer to the physical
drives or vice-versa. Cache is important because it can read and write data much
faster than a physical drive. There are read caches, which hold data as it is read
from a physical drive; and write caches, which hold data as it is written to a
physical drive.
In order to tune the cache for best performance in different applications, user-
adjustable settings are provided. Cache settings are made in conjunction with
logical drives:
•
When you create a logical drive. See “Creating a Logical Drive” on page 98
•
On an existing logical drive. See “Making Logical Drive Settings” on
page 107
Read Cache Policy
•
Read Cache – The read cache is enabled.
Logical Drive Size
Sector Size
8 to 16 TB
4096 bytes (4 KB)
4 to 8 TB
2048 bytes (2 KB)
2 to 4 TB
1024 bytes (1 KB)
0 to 2 TB
512 bytes (512 B)
Содержание VTRAK M610p
Страница 1: ...VTRAK M610p Product Manual Version 1 0 ...
Страница 30: ...VTrak M610p Product Manual 18 ...
Страница 44: ...VTrak M610p Product Manual 32 ...
Страница 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Страница 128: ...VTrak M610p Product Manual 116 ...
Страница 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Страница 274: ...VTrak M610p Product Manual 262 ...