Chapter 4: Management with WebPAM PROe
109
3.
Click the
icon of the logical drive you want to Initialize.
You can also start Redundancy check from the Subsystem
icon
Background Activities tab
4.
From the dropdown menu on the Background Activities tab, select
Redundancy Check
.
5.
To select
Auto Fix
, check the box.
This feature attempts to repair the problem when it finds an error.
6.
To select
Pause On Error
, check the box.
This feature stops the process when it finds an error.
If Auto Fix is also checked, the process stops only when it finds a non-
repairable error.
7.
Click the
Submit
button.
To view the progress of the Redundancy Check, click the Background Activity
tab.
To set Redundancy Check priority, see “Making Background Activity Settings” on
page 47.
Viewing the Logical Drive Check Table
The Logical Drive Check Table displays errors related to a logical drive. Use this
information to evaluate the integrity of the logical drive and to determine whether
corrective action is needed. To View the tables:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the Logical Drives
icon
5.
Click the Logical Drive
icon.
6.
Click the Check Table tab in Management View.
7.
Click the option for the table you want to see.
The default is All tables.
If there are entries, they are listed as follows:
•
Entry Number – A number assigned to each block of entry.
•
Table Type – Read Check, Write Check or Inconsistent Block (see
below).
•
Start Logical Block Address – LBA of the first block for this entry.
•
Count – Number of continuous blocks starting from this LBA.
Содержание VTRAK M610p
Страница 1: ...VTRAK M610p Product Manual Version 1 0 ...
Страница 30: ...VTrak M610p Product Manual 18 ...
Страница 44: ...VTrak M610p Product Manual 32 ...
Страница 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Страница 128: ...VTrak M610p Product Manual 116 ...
Страница 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Страница 274: ...VTrak M610p Product Manual 262 ...