Chapter 6: Maintenance
177
8.
When the download is completed, click the
Next
button.
A popup message appears to warn you not to reboot the VTrak during the
firmware update procedure.
9.
In the popup message, click the
OK
button.
The update progress displays. Then a popup message appears to tell you to
reboot the VTrak.
10. In the popup message, click the
OK
button.
11. Restart the VTrak. See “Restarting the Subsystem” on page 177.
Restarting the Subsystem
To restart the VTrak subsystem:
1.
Click on the Subsystem
icon in Tree View.
2.
Click on the Administrative Tools
icon.
3.
Click on the Shutdown link in Management View.
A Shutdown or Restart tab will appear.
4.
On the Shutdown or Restart tab, select
Restart
from the dropdown menu.
5.
Click the
Submit
button.
6.
In the warning box, click the
OK
button.
7.
In the confirmation box, type the word
confirm
in the field provided.
8.
Click the
OK
button.
When the controller shuts down, your WebPAM PROe connection will be
lost.
9.
Wait for two to three minutes.
10. In your browser, log into WebPAM PROe once again.
If you cannot log in, wait for 30 seconds, and try again. Repeat until login is
successful.
Note
After you click the
Submit
button, if WebPAM PROe displays this
message:
error transferring image
, you entered an incorrect file
name or an incorrect location. Check the information and try
again.
Warning
Do not restart the VTrak during a firmware upgrade procedure.
Wait until the upgrade is one and you are prompted to restart.
Содержание VTRAK M610p
Страница 1: ...VTRAK M610p Product Manual Version 1 0 ...
Страница 30: ...VTrak M610p Product Manual 18 ...
Страница 44: ...VTrak M610p Product Manual 32 ...
Страница 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Страница 128: ...VTrak M610p Product Manual 116 ...
Страница 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Страница 274: ...VTrak M610p Product Manual 262 ...