TECHNICAL INFORMATION
MAIN
CODE
SUB
CODE
DESCRIPTION
CHECK
TRANS
LIGHT
INHIBITED OPERATION
DESCRIPTION
44
21
Short to ground, F solenoid circuit
No
Lockup inhibited, DNA
44
22
Short to ground, G solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
23
Short to ground, H solenoid circuit
No
Differential lock inhibited
(3070 only), retarder
operation inhibited
44
24
Short to ground, J solenoid circuit
No
Low and 1st inhibited
44
26
Short to ground, N solenoid circuit
No
Low and 1st inhibited,
retarder allowed
45
12
Open circuit, A solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
13
Open circuit, B solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
14
Open circuit, C solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
15
Open circuit, D solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
16
Open circuit, E solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
21
Open circuit, F solenoid circuit
No
Lock-up inhibited, DNA
45
22
Open circuit, G solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
23
Open circuit, H solenoid circuit
No
Differential lock inhibited
(3070 only), retarder inhibited
45
24
Open circuit, J solenoid circuit
No
Low and 1st inhibited
45
26
Open circuit, N solenoid circuit
No
Low and 1st inhibited,
retarder allowed
46
21
Overcurrent, F solenoid circuit
No
Lock-up inhibited, DNA
46
26
Overcurrent, N and H solenoid circuits
No
Low and first inhibited or
retarder inhibited, DNA
46
27
Overcurrent, A-Hi solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
51
01
Offgoing ratio test (during shift),
Low to 1
Yes
DNS, RPR, DNA
51
10
Offgoing ratio test (during shift),
1 to Low
Yes
DNS, RPR, DNA
51
12
Offgoing ratio test (during shift),
1 to 2
Yes
DNS, RPR, DNA
51
21
Offgoing ratio test (during shift),
2 to 1
Yes
DNS, RPR, DNA
51
23
Offgoing ratio test (during shift),
2 to 3
Yes
DNS, RPR, DNA
51
24
Offgoing ratio test (during shift),
2 to 4
Yes
DNS, RPR, DNA
51
35
Offgoing ratio test (during shift),
3 to 5
Yes
DNS, RPR, DNA
51
42
Offgoing ratio test (during shift),
4 to 2
Yes
DNS, RPR, DNA
51
43
Offgoing ratio test (during shift),
4 to 3
Yes
(1)
DNS, RPR, DNA
8-12